7-3. AUTO RESTART FUNCTION

When the indoor unit is controlled with the remote controller, the operation mode, the set temperature, and the fan speed are memorized by the indoor electronic control P.C. board. The “AUTO RESTART FUNCTION” sets to work the moment power has restored after power failure. Then, the unit will restart automatically.

Operation

If the main power has been cut, the operation settings remain.

After the power is restored, the unit restarts automatically according to the memory. (However, it takes at least 3 minutes for the compressor to start running.)

How to release “AUTO RESTART FUNCTION”

Turn off the main power of the unit.

Solder the Jumper wire JR07 on the indoor electronic control P.C. board. (Refer to 9-7.)

CN211

JR07

BZ

 

 

CN152

 

CN112

 

CN101

 

 

 

 

CN151

 

 

 

 

 

NOTE:

The operation settings are memorized when 10 seconds have passed after the indoor unit was operated with the remote controller.

If main power is turned OFF or a power failure occurs while AUTO START/STOP timer is active, the timer setting is cancelled.

If the unit has been off with the remote controller before power failure, the auto restart function does not work as the power button of the remote controller is off.

To prevent breaker off due to the rush of starting current, systematize other home appliance not to turn on at the same time.

When some air conditioners are connected to the same supply system, if they are operated before power failure, the starting current of all the compressors may flow simultaneously at restart.

Therefore, the special counter-measures are required to prevent the main voltage-drop or the rush of the starting current by adding to the system that allows the units to start one by one.

11

Page 11
Image 11
Vermont Casting MSY-D30NA, MSZ-D36NA, MSZ-D30NA, MSY-D36NA service manual Auto Restart Function, Operation