9  TROUBLESHOOTING

9 9-1. CAUTIONS ON TROUBLESHOOTING1.Before troubleshooting, check the following TROUBLESHOOTING

MSZ-D30NA

MSZ-D36NA

MSY-D30NA

MSY-D36NA

9-1. CAUTIONS ON TROUBLESHOOTING

1.Before troubleshooting, check the following

1)Check the power supply voltage.

2)Check the indoor/outdoor connecting wire for miswiring.

2.Take care of the following during servicing

1)Before servicing the air conditioner, be sure to turn off the unit first with the remote controller, and then after confirm- ing the horizontal vane is closed, turn off the breaker and / or disconnect the power plug.

2)Be sure to turn OFF the power supply before removing the front panel, the cabinet, the top panel, and the electronic control P.C. board.

3)When removing the electronic control P.C. board, hold the edge of the board with care NOT to apply stress on the components.

4)When connecting or disconnecting the connectors, hold the housing of the connector. DO NOT pull the lead wires.

Lead wiring

Housing point

3.Troubleshooting procedure

1)First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate an abnormality. To make sure, check how many times the abnormality indication is flashing on and off before starting service work.

2)Before servicing check that the connector and terminal are connected properly.

3)If the electronic control P.C. board is supposed to be defective, check the copper foil pattern for disconnection and the components for bursting and discoloration.

4)When troubleshooting, refer to 9-2., 9-3. and 9-4.

4.How to replace batteries

Weak batteries may cause the remote controller malfunction.

In this case, replace the batteries to operate the remote controller normally.

2.Take care of the following during servicing Remove the front lid and insert batteries. Then reattach the front lid.

3.Troubleshooting procedure Press RESET button with tip end of ball point pen or the like, and then use the remote controller.

Insert the negative pole of the batteries first. Check if the polarity of the batteries is correct.

RESET button

NOTE : 1. If RESET button is not pressed, the remote controller may not operate correctly.

2.This remote controller has a circuit to automatically reset the microcomputer when batteries are replaced.