OPERATING PROCEDURE

PHOTOS

6. Removing the line flow fan and the indoor fan motor

Photo 7

(1)

Remove the panel and the corner box. (Refer to 1.)

 

 

 

(2)

Remove the electrical box. (Refer to 2.)

 

 

 

(3)

Remove the nozzle assembly. (Refer to 3.)

 

Screw of the motor band

 

(4)

Remove the water cover.

 

 

 

 

 

 

(5)

Loosen the screw of the line flow fan.

 

 

 

(6)Remove the screws of the motor bed.

(7)Remove the lead wire of the indoor coil thermistor from the

hooks of the motor bed.

 

(8) Remove the motor band and the motor bed together with

 

indoor fan motor. (Be careful not to drop the indoor fan

Screws of the motor bed

motor because it is heavy.)

 

(9)Remove the screw of the motor band, and remove the motor band then pull out the indoor fan motor.

(10)Remove the screws of the left side of the heat exchanger.

(11) Lift the left side of the heat exchanger.

Lead wire of the indoor

(12) Remove the line flow fan to the lower-left.

coil thermistor

 

Photo 8

Photo 9

Screws of the left side of the heat exchanger

Screw of the line flow fan