| OPERATING PROCEDURE | PHOTOS | ||
6. Removing the line flow fan and the indoor fan motor | Photo 7 | |||
(1) | Remove the panel and the corner box. (Refer to 1.) |
|
|
|
(2) | Remove the electrical box. (Refer to 2.) |
|
|
|
(3) | Remove the nozzle assembly. (Refer to 3.) |
| Screw of the motor band |
|
(4) | Remove the water cover. |
|
|
|
|
|
| ||
(5) | Loosen the screw of the line flow fan. |
|
|
|
(6)Remove the screws of the motor bed.
(7)Remove the lead wire of the indoor coil thermistor from the
hooks of the motor bed. |
| |
(8) Remove the motor band and the motor bed together with |
| |
indoor fan motor. (Be careful not to drop the indoor fan | Screws of the motor bed | |
motor because it is heavy.) | ||
|
(9)Remove the screw of the motor band, and remove the motor band then pull out the indoor fan motor.
(10)Remove the screws of the left side of the heat exchanger.
(11) Lift the left side of the heat exchanger. | Lead wire of the indoor | |
(12) Remove the line flow fan to the | ||
coil thermistor | ||
|
Photo 8
Photo 9
Screws of the left side of the heat exchanger
Screw of the line flow fan
33