(4) The initial set temperature is decided by the initial room temperature.
Model | Initial room temperature | Initial set temperature | ||
COOL mode of "I FEEL | 79 °F (26 °C) or more | 75°F (24 °C) |
| |
|
| 1 | ||
CONTROL" | 77 °F (25 °C) to 79 °F (26 °C) | Initial room temperature minus 4 °F (2 °C) | ||
| ||||
|
| |||
|
|
|
| |
DRY mode of "I FEEL | more than 55 °F (13 °C), | Initial room temperature minus 4 °F (2 °C) | ||
CONTROL" | less than 77 °F (25 °C) | |||
|
|
1 When the system is restarted with the remote controller, the system operates with the previous set temperature regardless of room temperature at restart.
The set temperature is calculated by the previous set temperature.
(5)TEMPERATURE buttons
In “I FEEL CONTROL” ( ) mode, set temperature is decided by the microprocessor based on the room temperature. In addition, set temperature can be controlled by TOO WARM or TOO COOL buttons when you feel too cool or too warm.
Each time the TOO WARM or TOO COOL button is pressed, the indoor unit receives the signal and emits a beep tone.
•Fuzzy control
When the TOO COOL or TOO WARM button is pressed, the microprocessor changes the set temperature, considering the room temperature, the frequency of pressing TOO COOL or TOO WARM button and the user’s preference to heat or cool. So this is called “Fuzzy control”, and works only in “I FEEL CONTROL” mode.
In DRY mode of “I FEEL CONTROL”, the set temperature doesn’t change.
··· To raise the set temperature 2 ~ 4 °F (1 ~ 2 °C)
··· To lower the set temperature 2 ~ 4 °F (1 ~ 2 °C)
8-6. AUTO CHANGE OVER ··· AUTO MODE OPERATION (MSZ)
Once desired temperature is set, unit operation is switched automatically between COOL and HEAT operation.
Mode selection
(1)Initial mode
When unit starts the operation with AUTO operation from off;
•If the room temperature is higher than the set temperature, operation starts in COOL mode.
•If the room temperature is equal to or lower than the set temperature, operation starts in HEAT mode.
(2)Mode change
COOL mode changes to HEAT mode when about 15 minutes have passed with the room temperature 4 °F (2 °C) below the set temperature.
HEAT mode changes to COOL mode when about 15 minutes have passed with the room temperature 4 °F (2 °C) above the set temperature.
14