5Maintenance and Troubleshooting

The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or sooner if a noticeable degradation in brightness occurs. Contact your Vidikron dealer to obtain a replacement lamp.

1.Turn off the projector and unplug the power cord. Allow the projector to cool down for approximately 45 minutes prior to removing the lamp assembly for replacement.

2.Loosen the four rear Lamp Cover screws and remove the cover.

3.Remove the two lamp assembly mounting screws.

4.Grasp the lamp assembly handle and pull gently, removing the lamp module from the projector housing.

5.Install the new lamp module.

6.Replace the lamp cover and re-tighten all screws.

7.Reset the Lamp Hour counter. To do this, select Service from the Main Menu, then Display Device, then Installation. Use the cursor buttons to highlight Reset under “Lamp Hours” and press ENTER.

Table 5-1provides some general guidelines for troubleshooting problems you may encounter with the Vision 90. If you encounter an issue not described here, please contact Vidikron Technical Support.

Table 5-1. Troubleshooting Chart

Symptom

Possible Cause(s)

Solution

 

 

 

The projector does not turn on

• The Vision 90 is not

• Ensure that the Vision 90 is

after initial installation. The

plugged in or the AC outlet

plugged in and that the AC

power LED lights red after you

is not active.

outlet is active.

press the power button.

 

 

 

 

 

The projector is on, but there is

• Incorrect source selection.

• Select the correct source.

no video image on-screen.

• Source component is not

• Turn on the source.

 

turned on.

 

 

 

 

A projected image from a DVD

• DVD player is set to

• Turn off progressive scan

is split or otherwise scrambled.

progressive scan mode.

on the DVD player.

 

 

• Connect the DVD player to

 

 

the HD/RGB 1 or HD/RGB 2

 

 

input.

 

 

 

Image is too bright and/or

• Contrast is set too high.

• Lower the contrast setting.

lacks definition in the bright

 

 

areas of the image.

 

 

 

 

 

Image appears “washed out”

• Brightness is set too high.

• Lower the brightness

and/or dark areas appear too

 

setting.

bright.

 

 

 

 

 

5.1

Lamp Replacement

5.2

Troubleshooting Tips

Vidikron Vision Model 90 Owner’s Operating Manual

5-1

Page 49
Image 49
Vidikron 90 manual 5Maintenance and Troubleshooting, Lamp Replacement Troubleshooting Tips, Troubleshooting Chart