Operation
Picture ➤
Picture
Brightness
Contrast
Color
Tint
Sharpness
Use the controls in the Picture Menu to calibrate your Vision 90 for optimum picture quality.
The Vision 90 has been designed to incorporate setup and calibration standards established by the Imaging Science Foundation (ISF). The ISF has developed carefully crafted,
All signal types require separate processing. Therefore, you need to calibrate each input separately. Vidikron recommends calibrating the Vision 90 inputs in the following order:
1.Component SD
2.
3.Composite
4.HD/RGB 1 / HD/RGB 2
5.DVI 1 / DVI 2
When you change a picture quality setting, save the change to a preset
Note afterwards. Otherwise, the change will be lost when a different input is selected. (Picture quality settings are saved for each input and resolution separately.) For information about saving settings, refer to ISF Presets on page
Although it may be possible to obtain satisfactory picture quality using the naked eye and regular program material, Vidikron recommends using the following calibration tools for best results:
•External test pattern source
•A blue filter (provided with many test DVDs), for color level and tint adjustments.
Connect your test pattern source to the input that you are calibrating and proceed as follows.
Perform the adjustments in the order listed here.
Brightness: On your external test pattern source, select a PLUGE pattern. (PLUGE is an acronym for “Picture
Below Black
Above Black
Figure 4-2. Typical PLUGE Pattern for Adjusting Brightness
Vidikron Vision Model 90 Owner’s Operating Manual |