LIMITS SETUP

!IMPORTANT: In the event of a complete power failure, including battery backup, the limits positions may have been cleared and will need to be reset by following the steps below.

STEP 1

Connect the “Motor Harness” to the Control Board.

a.“OPEN RIGHT” Connector if the gate opens to the Right, when viewed from inside.

b.“OPEN LEFT” Connector if the gate opens to the Leftt, when viewed from inside.

STEP 2

Move the gate to the desired open position then press and hold the “Open Limit” button until the LED stops flashing and illuminates solid.

1a 1b

STEP 3

Move the gate to the desired close position then press and hold the “Close Limit” button until the LED stops flashing and illuminates solid.

“Open Limit” LED flashes if the open limit is not set.

“Close Limit” LED flashes if the close limit is not set

Tip: The gate can be moved electronically with the “Open”, “Stop” and “Close” buttons on the Control Board or manually by following the instructions on page 11.

2 0

VIKING TECHNICAL SUPPORT 1.800.908.0884

 

 

Page 22
Image 22
Viking Access Systems H-10 manual Limits Setup, 1a 1b