TROUBLESHOOTING

LCD Display References

 

LCD MSG Meaning

Page 41

TS Ref #s

Multi Meter Displays

MOT AMP __._ A

MOT VOLT __._ VDC

AC VOLT __._ VAC

CHARGE __._ VDC

BAT VOLT __._ VDC

This is the motor current amperage during operation

This is the actual motor voltage during operation

This is the actual low voltage AC to the Control Board from the transformer

Indicates the charging voltage to the batteries, if the Battery Switch is in the OFF position.

Indicates battery voltage, if the AC power is discontinued to the Control Board.

EPS2

___% ERR

SPEED __%

OVERLAP _._ SEC

ODS SENS

___%

TIMER __ SEC

HEATER __ OFF

HEATER __ ON

LOCK MOD OFF

LOCK MOD ON

Board Settings Messages

Indicates that the Electronic Positioning Sensor (EPS) needs to be tuned. Error rate is displayed as a percentage

Shows the percentage of speed set by the Speed adjustment on the control board. (pg. 24)

Shows the number of seconds set by the Overlap Adjustment on the con- trol board. This feature is not available on slide gate operator models

Shows the force setting selected to trip the obstruction sensor. (pg. 26)

Shows the amount time set or remaining to hold the gate at the Open Limit position, before the gate starts to close. (pg. 24)

The Integrated Heater is disabled for the open “OPN” and/or close “CLS” limits (pg. 27)

The Integrated Heater has been enabled to turn on at the open “OPN” and/ or close “CLS” limits (pg. 27) “*” will be displayed while it is heating

The Lock Mode feature is turned OFF (pg. 27)

The Lock Mode feature is turned ON (pg. 27)

VIKING TECHNICAL SUPPORT 1.800.908.0884

3 9

 

 

Page 41
Image 41
Viking Access Systems H-10 manual Troubleshooting