VIVOTEK

 

 

 

 

 

 

 

 

 

 

 

 

 

vi

<integer>

6/6

Indicate the source id of vi trigger.

 

 

 

 

 

This field is required when trigger condition is “vi”.

 

 

 

 

 

One bit represents one digital input. The LSB

 

 

 

 

 

indicates VI 0.

 

 

 

 

 

 

 

 

mdwin

<integer>

6/6

Indicate the source window id of motion detection.

 

 

 

 

 

This field is required when trigger condition is “md”.

 

 

 

 

 

One bit represents one window.

 

 

 

 

 

The LSB indicates the 1st window.

 

 

 

 

 

For example, to detect the 1st and 3rd windows, set

 

 

 

 

 

mdwin as 5.

 

 

 

 

 

 

 

 

mdwin0

<integer>

6/6

Similar to mdwin. The parameter takes effect when

 

 

 

 

 

profile 1 of motion detection is enabled.

 

 

 

 

 

 

 

 

inter

1~999

6/6

Interval of snapshots in minutes.

 

 

 

 

 

This field is used when trigger condition is “seq”.

 

 

 

 

 

 

 

 

weekday

0~127

6/6

Indicate which weekday is scheduled.

 

 

 

 

 

One bit represents one weekday.

 

 

 

 

 

bit0 (LSB) = Saturday

 

 

 

 

 

bit1 = Friday

 

 

 

 

 

bit2 = Thursday

 

 

 

 

 

bit3 = Wednesday

 

 

 

 

 

bit4 = Tuesday

 

 

 

 

 

bit5 = Monday

 

 

 

 

 

bit6 = Sunday

 

 

 

 

 

For example, to detect events on Friday and Sunday,

 

 

 

 

 

set weekday as 66.

 

 

 

 

 

 

 

 

begintime

hh:mm

6/6

Begin time of the weekly schedule.

 

 

 

 

 

 

 

 

endtime

hh:mm

6/6

End time of the weekly schedule.

 

 

 

 

 

(00:00 ~ 24:00 sets schedule as always on)

 

 

 

 

 

 

 

 

action_do_i<0~(ndo-1)>

0, 1

6/6

Enable or disable trigger digital output.

 

 

_enable

 

 

 

 

 

 

 

 

 

 

 

action_do_i<0~(ndo-1)>

1~999

6/6

Duration of the digital output trigger in seconds.

 

 

_duration

 

 

 

 

 

 

 

 

 

 

 

action_wled_i<0~(nwled-

0, 1

6/6

Enable or disable trigger white light LED.

 

 

1)>_enable

 

 

 

 

 

 

 

 

 

 

 

action_wled_i<0~(nwled-

1~999

6/6

Duration of the white light LED trigger in seconds.

 

 

1)>_duration

 

 

 

 

 

 

 

 

 

 

 

action_server_i<0~4>_en

0, 1

6/6

Enable or disable this server action.

 

 

able

 

 

 

 

 

 

 

 

 

 

 

action_server_i<0~4>_m

NULL,

6/6

Index of the attached media.

 

 

edia

0~4,101

 

101: recording notify

 

 

 

 

 

 

 

User's Manual - 143

Page 143
Image 143
Vivotek IP8132 manual Null