VIVOTEK

maskheight

integer

3D privacy mask height

 

 

 

maskwidth

integer

3D privacy mask width

 

 

 

return

<return page>

Redirect to page <return page> after the 3D privacy mask is

 

 

configured. The <return page> can be a full URL path or relative

 

 

path according to the current path. If you omit this parameter, it

 

 

will redirect to an empty page.

 

 

 

Query Status of the Digital Input

Note: This request requires Viewer privileges.

Method: GET/POST

Syntax:

http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]

If no parameter is specified, all of the digital input statuses will be returned.

Return:

HTTP/1.0 200 OK\r\n Content-Type: text/plain\r\n Content-Length: <length>\r\n \r\n

[di0=<state>]\r\n

[di1=<state>]\r\n

[di2=<state>]\r\n

[di3=<state>]\r\n

where <state> can be 0 or 1.

Example: Query the status of digital input 1.

Request:

http://myserver/cgi-bin/dido/getdi.cgi?di1

Response:

HTTP/1.0 200 OK\r\n Content-Type: text/plain\r\n Content-Length: 7\r\n \r\n

di1=1\r\n

136 - User's Manual

Page 136
Image 136
Vivotek SD8111 manual Query Status of the Digital Input, Di0=state\r\n Di1=state\r\n Di2=state\r\n Di3=state\r\n