VIVOTEK
Group: event_i<0~2>
PARAMETER |
| VALUE |
| SECURITY |
| DESCRIPTION |
|
|
|
|
| (get/set) |
|
|
|
name |
| string[40] |
| 6/6 |
| Identification of this entry. | |
|
|
|
|
|
|
| |
enable |
| 0, 1 |
| 6/6 |
| Enable or disable this event. | |
|
|
|
|
|
|
| |
priority |
| 0, 1, 2 |
| 6/6 |
| Indicate the priority of this event: | |
|
|
|
|
|
| “0” = low priority | |
|
|
|
|
|
| “1” = normal priority | |
|
|
|
|
|
| “2” = high priority | |
|
|
|
|
|
|
| |
delay |
| 1~999 |
| 6/6 |
| Delay in seconds before detecting the next event. | |
|
|
|
|
|
|
| |
trigger |
| boot, |
| 6/6 |
| Indicate the trigger condition: | |
|
| di, |
|
|
| “boot” = System boot | |
|
| motion, |
|
|
| “di”= Digital input | |
|
| seq, |
|
|
| “motion” = Video motion detection | |
|
| recnotify, |
|
|
| “seq” = Periodic condition | |
|
|
|
|
|
| “recnotify” = Recording notification. | |
|
|
|
|
|
|
| |
triggerstatus |
| String[40] |
| 6/6 |
| The status for event trigger | |
|
|
|
|
|
|
| |
di |
| <integer> |
| 6/6 |
| Indicate which DI detects. | |
|
|
|
|
|
| This field is required when trigger condition is “di”. | |
|
|
|
|
|
| One bit represents one digital input. The LSB | |
|
|
|
|
|
| indicates DI 0. | |
|
|
|
|
|
|
| |
mdwin |
| <integer> |
| 6/6 |
| Indicate which motion detection windows detect. | |
|
|
|
|
|
| This field is required when trigger condition is “md”. | |
|
|
|
|
|
| One bit represents one window. | |
|
|
|
|
|
| The LSB indicates the 1st window. | |
|
|
|
|
|
| For example, to detect the 1st and 3rd windows, set | |
|
|
|
|
|
| mdwin as 5. | |
|
|
|
|
|
|
| |
mdwin0 |
| <integer> |
| 6/6 |
| Similar to mdwin. The parameter takes effect when | |
|
|
|
|
|
| profile 1 of motion detection is enabled. | |
|
|
|
|
|
|
| |
inter |
| 1~999 |
| 6/6 |
| Interval of snapshots in minutes. | |
|
|
|
|
|
| This field is used when trigger condition is “seq”. | |
|
|
|
|
|
|
|
|
User's Manual - 129