Trigger setting (when Event classification is set to BGM END)
EVENT01TRI
G
C- IN01
Activating the selected Event terminates all Events for Priority-8 inputs.
Set the control input that activates the Event termination.
36
EVENT01 C
O
U
T
01
Interlock output terminal setting (when Event classification is set to ROUTE)
Set the control output terminals 1 4 (1 12 when the C-001T is used) which are closed in synchronization
with the Event's activation.
EVENT01 SYNC
O
N
Interlock output control ON/OFF setting (when Event classification is set to ROUTE)
Set whether or not to close the control output terminal in synchronization with the Event's activation.
ON: Control output terminal is closed when the Event is activated. (The terminal is continuously closed
during Event activation.)
OFF: Control output does not interlock with the Event's activation.
Trigger setting (when Event classification is set to ROUTE)
EVENT01TRI
G
C- IN01
Set how to activate the selected Event.
C-IN1 to C-IN04 (C-IN1 to C-IN2 when the C-001T module is used):
Closing the designated control input terminal activates the Event.
VOX: The event is activated when the selected input channel receives a signal.
Note
The D-001T module must be used for input, and the VOX set to ON in the audio input setting.
NONE: External control cannot be used for activation. Set the trigger setting here to NONE when
designating the selected Event number as a BGM pattern.
ON, OFF (default)
Setting Range
NONE (default), VOX, C-IN01 04 (C-IN01 12 when C-001T is used)Setting Range
C-IN01 04, C-IN01 12 when C-001T is used (default: C-IN01)
Note: The control input terminals that have already been set cannot be used.
Setting Range
COUT01 04, C-OUT01 12 when C-001T is used (default: COUT01)
Note: When the interlock output control ON/OFF setting is ON.
Setting Range