40
12.7.2. Utility setting items
•CIN: Sets the functions to be assigned to the control input terminals. Assigning a function to the
control input terminal preset to "Event-Trigger" cancels the "Event-Trigger" function, being
replaced with the new function.
•COUT: Sets the functions to be assigned to the control output terminals.
•POWER OFF: Sets whether or not to save data of the volume level set in normal operation mode when the
AC power supply is cut off.
•RS232C: Sets the RS-232C communication speed.
•MODULE: Displays or sets the module classification.
•PRIORITY: Sets priority order when multiple inputs with the same priority are broadcast.
•REMOTE: Sets the input and output channels for which the volume is remotely adjusted.
•EVENT: Sets the Event that is activated when the unit's power is turned on.
•VERSION: Displays the firmware version.
•MEMORY: Initializes memory.
Function selection
UTILITY C-
I
N
Unless otherwise specified, use the Parameter setting knob for each parameter selection.
NONE (default), VOLUP (volume up), VOLDOWN (volume down), MUTE, POWER,
EMG-MUTE (Cut-off by Emergency control)
Setting Range
C-IN (control input, default), C-OUT (control output), POWEROFF, RS232C, MODULE,
PRIORITY, REMOTE (remote volume), EVENT (Event activation at power-on),
VERSION, MEMORY (memory initialization)
Setting Range
01 – 04, 01 – 12 when C-001T is used (default: 01)
Setting Range
Control input number selection
C- IN01– N
O
N
E
When the Down shift key is pressed with the control input function set to NONE and the cursor at the control
input number, the Event number assigned to that control input number can be confirmed.
If no Event is assigned to that control input number, the NONE indication is displayed.
[When the function is set to C-IN:]
Control input function setting
C- IN01– N
O
N
E
Sets the functions to be assigned to the control input terminals.
C-IN01 EVENT N
O
NE
Event assignment display
When the displayed control input (C-IN01 in this example) is set to Trigger in the Event setting, the Event
number is displayed.
If the control input is not set to Trigger, the NONE indication is displayed.
Assigning a function to the control input terminal preset to "Event-Trigger" cancels the "Event-Trigger"
function, being replaced with the new function.