Set the volume level (dB) to increase or decrease.
41
(When the control input function is set to VOLUP:) (When the control input function is set to VOLDOWN:)
C- IN01– V
O
LU
P
C- IN01– V
O
LD
O
W
N
Assign the volume-up or volume-down function to the control input.
Closing the control input terminal increases or decreases the volume of the set input or output channel.
C- IN01– V
O
LUP IN
1
Channel number selection (VOLUP)
C- IN01– V
O
LD
W
N IN
1
Channel number selection (VOLDOWN)
Using the Input channel or Output channel selection key, select the channel number for which you want to
change the volume.
One control input can change one input or output channel volume.
You can change the sound volume for a channel even with the channel off, but not adjust it while monitoring
the sound.
0.5 – 10.0 dB (default: 0.5)
Setting Range
IN1 – 8 (default: IN1)
Setting Range
Volume increasing level setting (VOLUP)
C- IN01– V
O
LUP 05
.
Volume decreasing level setting (VOLDOWN)
C- IN01– V
O
L
D
W
N
05
.
(When the control input function is set to MUTE:)
C- IN01–
M
UT
E
Assign the function that mutes the input or output channel to the control input.
Closing the control input terminal mutes the set channel.
An input channel, when muted while in use, occupies the routed output, causing the Event-activated
broadcast by the input channel with lower priority not to go through to the same output channel.
Channel number selection (MUTE)
C- IN01–
M
UTE IN
1
Using the Input channel or Output channel selection key, select the channel number to be muted.
One control input can mute one input or output channel.
IN1 – 8, OUT1 – 2, Max. OUT8 when T-001Ts are added (default: IN1)
Setting Range
Interlock output control setting (MUTE)
C- IN01– SYNC
O
FF
Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the
control input terminal closure of the set number.
ON, OFF (default)
Setting Range