Interlock output terminal setting (MUTE)
C- IN01 C
O
UT01
This screen is displayed only when the interlock output control setting is set to ON.
Set the control output terminal which is closed in synchronization with the control input of the set number.
Setting the control output terminal that has been already set as interlock output terminal in the Event setting
cancels the former Event-interlocked output.
(When the control input function is set to POWER:)
C- IN01 P
O
W
E
R
Assign the power ON/OFF function to the control input.
Power turns on when the control input terminal is closed, and turns off when the control input terminal is
opened.
(When the control input function is set to EMG-MUTE:)
C- IN01 E
MG
-
M
UT
E
Assign the function that simultaneously mutes all output channels to the control input. Closing the control input
terminal mutes all output channels.
This function is used to mute the output provided from the unit during emergency broadcast operation.
COUT01 04, C-OUT01 12 when C-001T is used (default: COUT01)
Note: When the interlock output control ON/OFF setting is ON.
Setting Range
Interlock output terminal setting (EMG-MUTE)
C- IN01 C
O
UT01
This screen is displayed only when the interlock output control setting is set to ON.
Set the control output terminal which is closed in synchronization with the control input of the set number.
Setting the control output terminal that has been already set as interlock output terminal in the Event setting
cancels the former Event-interlocked output.
COUT01 04, C-OUT01 12 when C-001T is used (default: COUT01)
Note: When the interlock output control ON/OFF setting is ON.
Setting Range
Interlock output control setting (EMG-MUTE)
C- IN01 SYNC
O
FF
Perform ON/OFF setting for the function that closes the control output terminal in synchronization with the
control input terminal closure of the set number.
ON, OFF (default)
Setting Range