44
9.6 k, 19.2 k, 38.4 k, 57.6 k (default), 115.2 k
Setting Range
Communication speed (bps) setting
.
SER I AL SPEED= 576
[When the function is set to RS232C:]
[When the function is set to MODULE:]
Slot number selection and 900 series module classification setting
SL
O
T 1 =
O
THERS
Use the Left and Right shift keys to move the setting items on the screen.
For slots equipped with 9000 Series plug-in modules, their module model numbers are automatically
displayed and cannot be changed. For slots equipped with 900 Series input modules, select their model
numbers using the Parameter setting knob.
The settings performed here are merely displayed, and have no effect on the audio input and other settings.
1 8 (default: 1)
OTHERS (default), B-01, B-11, B-21, B-41, E-03, E-04, E-05,
E-06, E-07, L-01, L-11, L-41, M-01, M-03, M-11, M-21, M-41,
M-51, M-61, S-01, S-02, S-04, T-01, T-02, T-12, U-01, U-03,
U-11, U-12, U-13, U-14, U-21, U-43, U-61, V-01, ML-11T
Setting Range Slot Number
Module Classification
REMOTE 1, REMOTE 2
OFF, INPUT1 8, OUTPUT1 2, Max. OUTPUT8 when T-001T is used
(default for REMOTE1: OUTPUT1, REMOTE2: OUTPUT2)
Setting Range
Remote Volume
Terminal Number
Remote Volume
Control Channel
Priority setting
P
R
I
O
RI
T
Y
FI
F
O
Set priorities when multiple inputs with the same priority level are simultaneously broadcast.
FIFO: Input that comes first is broadcast.
LIFO: The most recent input is broadcast.
MIX: All inputs are mixed and broadcast.
[When the function is set to PRIORITY:]
FIFO (default), LIFO, MIX
Setting Range
Remote volume control channel setting
R
E
M
O
TE1
O
UTPUT1
Set the input or output channels for which the volume is remotely adjusted by way of the unit's rear panel-
mounted control I/O connection terminal.
The indication REMOTE 1 refers to the REMT VOL 1 terminal of the control I/O connection terminal, while the
indication REMOTE 2 represents the REMT VOL 2 terminal.
Use the Left and Right shift keys to move the setting items on the screen.
[When the function is set to REMOTE:]