Wayne-Dalton 6100 installation instructions TorqueMaster Plus Reset, Instructions

Models: 6100

1 36
Download 36 pages 62.71 Kb
Page 29
Image 29
TorqueMaster® Plus Reset

TorqueMaster® Plus Reset

ENGAGEMENT SIDE VIEW

 

 

 

 

Instructions

 

 

 

Tools Needed:

IMPORTANT! THE OPENER FORCE

 

 

 

SETTINGS MUST BE ADJUSTED

 

 

 

 

 

 

 

5/8” Socket

ACCORDING TO THE MANUFACTURER’S

Ratchet

 

 

Ratchet Wrench

INSTRUCTIONS. SOME LIGHTER WEIGHT

Pawl

 

 

DOORS ARE DESIGNED TO OPERATE WITH

 

 

 

 

 

3” Extension

A SINGLE COUNTER-BALANCE SPRING. IF

 

 

 

THAT COUNTER-BALANCE SPRING

 

 

 

 

 

 

 

Vice Clamps

BREAKS AND THE OPENER’S FORCE

 

 

 

SETTINGS ARE NOT ADJUSTED

 

 

 

(Pair)

 

 

 

ACCORDING TO THE MANUFACTURER’S

 

 

 

 

 

 

 

3” Extension

SPECIFICATIONS, THE OPENER MAY THEN

 

 

 

 

HAVE THE CAPABILITY OF LIFTING THE

 

Cable Drum

 

 

DOOR TO THE OPEN POSITION, DESPITE

 

 

 

 

 

 

 

THE BROKEN COUNTER-BALANCE

 

 

 

 

SPRING. THIS SCENARIO WILL CAUSE THE

 

 

 

 

COUNTER-BALANCE CABLES TO GO

 

 

 

 

SLACK AND ENGAGE THE

drum Pawl

 

 

 

TORQUEMASTER® PLUS SAFETY SYSTEM.

 

 

 

 

No space between

 

 

IF A PERSON IS UNAWARE OF THE SLACK

 

 

 

 

drum Pawl and Cable

 

 

CABLES AND THE ENGAGED

ENGAGEMENT Underneath View

 

 

Drum

 

 

TORQUEMASTER® PLUS SAFETY SYSTEM

 

 

 

 

indicates engagement

 

 

AND ACTIVATES THE MIS-ADJUSTED

 

 

 

 

 

 

 

OPENER, DAMAGE WILL LIKELY OCCUR TO

 

 

 

 

THE DOOR AND OPENER. THE POTENTIAL

 

 

 

 

ALSO EXISTS THAT THE PERSON

 

 

 

 

ACTIVATING THE OPENER UNDER THIS

 

 

 

 

SCENARIO COULD BE SEVERELY INJURED.

drum Pawl and

 

 

 

WARNING

 

 

 

 

No space between

 

 

 

READ THESE INSTRUCTIONS CAREFULLY

Cable Drum

 

 

 

BEFORE ATTEMPTING TO RESET THE

 

 

 

 

TORQUEMASTER® PLUS SYSTEM. IF IN

NON-ENGAGEMENT SIDE VIEW

 

 

QUESTION ABOUT ANY OF THE

 

 

 

 

PROCEDURES, DO NOT PERFORM THE

 

 

 

 

WORK. INSTEAD, HAVE A TRAINED DOOR

 

 

 

 

SYSTEMS TECHNICIAN RESET THE

 

 

INSTALLATION

 

SYSTEM.WARNING

 

 

 

 

 

 

 

TO AVOID SEVERE OR FATAL INJURY, DO

 

 

 

 

NOT STAND OR WALK UNDER A MOVING

 

 

 

 

DOOR, OR PERMIT ANYONE TO STAND OR

 

 

 

 

WALK UNDER AN ELECTRICALLY

 

 

Optional

 

OPERATED DOOR

 

 

 

This door is equipped with a

 

 

 

 

TorqueMaster® Plus system, a safety

 

Cable Drum

 

 

feature which prevents the door from

 

 

 

rapidly descending in case of spring

 

 

 

 

failure or forceful manual operation. If the

 

 

 

 

system engages with the door in the open

 

 

 

 

position, personal items that are left

 

 

 

 

unattended in the garage or home are at

drum Pawl

 

 

 

risk to theft. To insure the safekeeping of

 

Space between DRUM Pawl

 

 

these items, close the garage door.

 

and Cable Drum

 

 

Typical signs of an engaged system:

NON-ENGAGEMENT Underneath View

non-indicates engagement

 

 

Single spring system: Visually inspect

 

 

 

 

the TorqueMaster® Plus right hand end

 

 

 

 

bracket to confirm that the system has

 

 

 

 

engaged (see illustration). If the system is

 

 

 

 

engaged then the door will not close. If

 

 

 

 

the opener force settings were properly

 

 

 

 

set during the initial installation, the door

 

 

 

 

will not open. If the opener can physically

Space between

 

 

 

overcome the weight of the door and lift it

drum Pawl and

 

 

 

to the open position, then the

Cable Drum

 

 

 

counterbalance cables will be slack.

 

 

 

 

 

 

 

 

 

 

29

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer. To find your local Wayne-Dalton dealer, refer to your

local yellow pages/business listings or go to the Find a Dealer section online at www.wayne-dalton.com

Page 29
Image 29
Wayne-Dalton 6100 installation instructions TorqueMaster Plus Reset, Instructions