Wayne-Dalton 6100 installation instructions Side Lock, Pull Rope, optional INSTALLATION

Models: 6100

1 24
Download 24 pages 37.63 Kb
Page 21
Image 21
Side Lock

Side Lock

 

 

 

Tools Needed:

Install the side lock on the second section of the door.

Secure the lock to the section with (4) 1/4”-20 x

Power Drill

11/16” self drilling screws. Square the lock assembly

 

7/16” Socket Driver

with the door section, and align with the square hole

Tape Measure

in the vertical track. The side lock should be spaced

approximately 1/8” from the section edge.

 

IMPORTANT: side locks must be removed or

 

made inoperative in the unlocked position if

 

an operator is installed on the door.

 

NOTE: After completing this step, continue with Step

 

6 on page 10.

(4) 1/4”- 20 X 11/16” self drilling screws

1/8”

 

Pull Rope

 

 

 

 

 

 

 

 

 

 

Tools Needed:

 

WARNING

 

 

 

Power Drill

 

 

 

DO NOT INSTALL PULL ROPES ON DOORS WITH

Drill Bit

ELECTRIC OPERATORS. CHILDREN MAY BECOME

 

ENTANGLED IN THE ROPE CAUSING SEVERE OR FATAL

 

INJURY.

 

Pilot drill the location for the No. 6 screw eye.

 

Screw the No. 6 screw eye into the wood jamb

 

approximately 48” to 50” (1220 to 1270 mm) from

 

the floor. Tie the pull rope to the screw eye and to the

 

bottom bracket as shown.

No. 6 screw eye

Pull rope

Pull rope

optional INSTALLATION

Bottom bracket

21

Please Do Not Return This Product To The Store. Contact your local Wayne-Dalton dealer. To find your local Wayne-Dalton dealer, refer to your

local yellow pages/business listings or go to the Find a Dealer section online at www.wayne-dalton.com

Page 21
Image 21
Wayne-Dalton 6100 installation instructions Side Lock, Pull Rope, optional INSTALLATION