Image 26
6Field wiring

GOLD CGs Gas-Fired Water Boiler

6Field wiring

For your safety, turn off electrical power supply at service entrance panel before making any electrical

connections to avoid possible electric shock hazard. Failure to do so can cause severe personal injury or death.

Wiring must be N.E.C. Class 1.

Wiring connections

Boiler is shipped with controls completely wired.

Thermostat

1.Connect thermostat as shown on wiring diagram on boiler.

2.Install on inside wall away from influences of drafts, hot or cold water pipes, lighting fixtures, television, sunrays, or fireplaces.

If original wiring as supplied with boiler must be replaced, use only type 105 °C wire or equivalent.

Boiler must be electrically grounded as required by National Electrical Code ANSI/NFPA 70 – latest edition.

3.If thermostat has a heat anticipator, set heat anticipator in thermostat to match power requirements of equipment connected to it. If connected directly to boiler, set for 0.4 amps. For other devices, refer to manufacturer’s specifications. Wiring diagram on boiler gives setting for control module and gas valve. Also see instructions with thermostat.

Electrical installation must comply with:

1.National Electrical Code and any other national, state, provincial or local codes or regulations.

2.In Canada, CSA C22.1 Canadian Electrical Code Part 1, and any local codes.

Junction Box (furnished)

1.Connect 120 VAC power wiring as shown in

Figure 15.

2.Fused disconnect or service switch (15 amp. recommended) may be mounted on this box. For those installations with local codes which prohibit installation of fused disconnect or service switch on boiler, install a 2 x 4 cover plate on the boiler junction box and mount the service switch remotely as required by the code.

Figure 15

Field wiring connections — service switch and thermostat (or end switch) provided by installer

The CGs control module is polarity-sensitive. The hot and neutral wires must be connected to the correct leads. A flashing POWER light usually indicates reversed polarity of 120 VAC lead wires.

Field wiring

Factory wiring

120 VAC

 

 

Hot

Neutral

Ground

Thermostat

or end switch

(not provided)

Service switch

(not provided)

 

 

Ground screw

 

Wire nuts

Black

White

Green

Black

Black

 

 

T h e r m o s t a t

Junction box,

 

leads, through

boiler left side

 

jacket left side

 

 

26021

 

 

Service switch

(not provided)

Thermostat or end switch

(not provided)

26

Part number 550-110-260/0200

Page 26
Image 26
Weil-McLain 550-110-260/02002 6Field wiring, Wiring connections, Electrical installation must comply with, Thermostat