WhisperKool 5000TI Back of unit, Liquid Measuring Thermostat System, Placement of Unit, Do not

Models: 5000TI 5000TIR

1 42
Download 42 pages 612 b
Page 17
Image 17
Placement of Unit

Placement of Unit

Slide the unit from the outside wall into your wine cellar with the outer flange flush to the wall. Secure the flange to the wall through the pre-drilled holes. The screws should penetrate the studs as well as the upper and lower supports to provide adequate support for the WhisperKOOL system (see illustration). Seal all cracks and gaps around the WhisperKOOL Extreme unit with an air-tight sealant or caulking to prevent air leakage.

Note: If you use decorative molding, it should be attached to the walls and never to the cooling unit itself.

Note: The screws to the flange should not be covered in case the unit needs to be removed for servicing.

2x4 Upper Support

Wall Stud

Mounting Flange

 Back of unit Back of unit

2x4 Lower Support

Location of Supply and Return GrillesDo not:Liquid Measuring Thermostat SystemManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background Drain Port

Electrical Outlet

Location of Supply and Return Grilles

Locate the supply and return grilles inside the cellar to create an airflow pattern that maximizes air circulation in the room. Avoid short circulation of the air.

Do not:

Install through-the-wall return air grilles at floor level, as they will collect dust from the floor.

Mount the unit lower than 18” from the ceiling.

Locate the supply or return air grille where it is blocked by bottles, boxes or cases.

Liquid Measuring Thermostat System

To assure a consistent temperature, place bottle probe approximately 3 feet away from the air output and not in the flow of the air.