Set

1.

Press the “Set” button once and it will display the Set Point. After approximately 5

Button

 

seconds, the display will return to normal operation and display the Bottle Probe

 

 

temperature.

 

2.

Press the “Set” button once and it will display the Set Point. Press the up and down

 

 

arrows to change the set point. Press the Set button again and the numbers will

 

 

blink, confirming the change in Set Point.

 

3.

Press and hold the “Set” button during the display of the Hi/Low “Temperature Data

 

 

History” (hold button unit “rst” blinks on display), and it will erase the past recorded

 

 

data file and start recording, from the current time and temperature.

 

4.

Press the “Set” and the “Down Arrow” buttons simultaneously, for 3-5 seconds, and

 

 

you will access the “Customer Preference Selection Mode” (CPSM). The CPSM allows

 

 

the customer to “Fine Tune” the Control Operating System to their applicable choice.

CPSM Mode

Press the “Set” and the “Down Arrow” buttons simultaneously, for 3-5 seconds, and you

 

will access the “Customer Preference Selection Mode” (CPSM). The CPSM allows the

 

customer to “Fine Tune” the Control Operating System to their applicable choice.

 

The following CPSM options are available for adjustment:

Fon – Humidity Management Enhancement: This parameter is normally set at 0, which should provide adequate relative humidity for the cellar.

An increase in this parameter will increase the Humidity Enhancement (%RH), and a decrease in the parameter will decrease Humidity Enhancement (%RH).

Adjustments should be made in increments of 5, with a maximum of 15, and a minimum of 0.

After any adjustment to Humidity Enhancement, you should wait a minimum of three days before making any additional adjustments. This will allow the cellar suf- ficient time to acclimate to the new setting.

Fof - Humidity Management Enhancement: This parameter is normally set at 15. This parameter should not be adjusted, as it simply provides an OFF cycle time for the fan, during the compressor OFF cycle. However, the parameter is located within the CPSM as a convenience to the customer, should it need to be adjusted.