ATTACH THERMOSTAT TO SUBBASE
WE RECOMMEND THAT YOU SET OPTION SWITCHES TO DESIRED POSITION BEFORE AT- TACHING ON SUBBASE (see OPERATION). WE
ALSO RECOMMEND THAT YOU PROGRAM THE THERMOSTAT WITH BATTERY INSTALLED BE- FORE ATTACHING ON SUBBASE (see OPERA- TION section for programming instructions).
USE | SYSTEM | TO TURN THERMOSTAT OFF BE- |
FORE ATTACHING TO WALL. FAILURE TO TURN OFF THERMOSTAT BEFORE ATTACHING TO WALL MAY CAUSE EQUIPMENT DAMAGE DUE TO RAPID COMPRESSOR CYCLING.
To attach thermostat to subbase, line up the plastic snap guides at the top of the thermostat and the 4 connector pins on the thermostat with the connec- tors near the top right section of the subbase (when viewed from the front). Gently pivot the thermostat down until the
snaps lock into place (see fig. 7). Be gentle when attaching thermostat. If the thermostat does not seem to be attaching to the subbase easily, make sure that the connector pins and plastic snaps are properly aligned, and that excess wire is pushed into the wall. Damage to the thermostat may occur if force is used.
ENGAGE TWO UPPER GUIDES; PIVOT DOWN
Figure 7. Attaching thermostat to subbase