White Rodgers HC-TST501CMMS manual Furnace User Menus Cont, Select continuous FAN speed

Models: HC-TST501CMMS

1 18
Download 18 pages 1.72 Kb
Page 11
Image 11
Furnace User Menus (Cont.)

Advanced Installer Configuration Menu

Thermostat Setup

Furnace User Menus (Cont.)

Unit Info

Parameter

 

 

Indications

 

Comments

 

 

 

 

Model Number

XXXX-XXXXXXXXXXXXXXXX

Unit Model Number

Serial Number

XXXXXXXXXXXXXXXXXXX

Unit Serial Number (Not available if

 

 

 

 

 

 

control is replaced)

 

 

 

 

 

Software Vers

XXXXXX

 

 

Control Software Version

 

 

 

 

 

 

 

 

Setup

 

 

 

 

 

 

 

Parameter

 

Options

 

 

 

Comments

 

 

 

 

Heat Rise Adjust

55F, 65F

 

Change airflow to adjust heat temperature rise

 

 

 

Min Heat Adj %

-15, -7, 0, 7, 15

Selectable Airflow Adjustments at 40% Firing Rate

Max Heat Adj %

-15, -7, 0, 7, 15

Selectable Airflow Adjustments at 100% Firing Rate

 

 

 

 

Supply Air Sens

On, Off

 

Factory default is On, if Sensor is not installed

 

 

 

 

 

turn Off

 

 

Reset All Dflts

No, Yes

 

Resets the Furnace to the Factory Default

 

 

 

 

 

Configuration by selecting Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dipswitch*

 

 

 

 

 

 

 

Dip Switch

 

 

 

Indications

 

Comments

 

 

 

 

 

 

 

Cool Airflow

 

 

XXXXCFM

 

Airflow Dipswitch Settings

 

 

 

 

 

 

 

Heat Rise

 

 

Nom, Nom+10

 

Heat Rise Airflow Settings

 

 

 

 

 

 

 

Hi Heat Adj

 

 

-15%, -7%, 0%, 7%, 15%

 

High Heat Airflow Settings

 

 

 

 

 

 

 

Lo Heat Adj

 

 

-15%, -7%, 0%, 7%, 15%

 

Low Heat Airflow Settings

 

 

 

 

 

 

 

 

Fan Spd Select

 

 

Lo, Hi

 

 

 

Fan Speed Settings

 

 

 

 

 

 

 

AC-HP Adj

 

 

-10%, 0%, 10%

 

Heat Pump AC Airflow Settings

 

 

 

 

 

 

 

 

On-Demand Dehum

 

On, Off

 

 

 

Dehumidification Settings

 

 

 

 

 

 

 

Test Mode

 

 

Off, 40% (70%), 100%

 

Test Mode Settings

 

 

 

 

 

 

 

AC HP Stg Mult

 

 

NA, 50%, 75%

 

Heat Pump AC Stage Multiplier

 

 

 

 

 

 

 

 

*Dipswitch status is not required when the system is set up for 4-wire communications. It is only displayed when a conventional 24V thermostat input is active.

1

2

1

2

1

2

Select continuous FAN speed.

Default is Medium. It can be set to High, Medium or Low. In High, the fan will run at the highest speed when FAN key is selected to On. In high, the fan speed will be at high speed, in medium the fan speed will be approximately 60% of high, and in low the fan speed will be approximately 30% of high.

Select program days per week.

Scrolling message will show “PROGRAM TYPE”. Default is 7 Days to indicate individual day programming. It can be changed to 0 Days to indicate no programs will be run. When set for 7 Days, the thermostat will follow the factory program or the program that you entered.

Select Energy Management Recovery.

Scrolling Message will show “ENERGY MANAGEMENT RECOVERY”. (Will not appear if Program days per week is set to 0 Days.) When selected On, the thermostat will begin heating or cooling early to have the temperature reach the program setpoint at the program period start time.

Example: The heating program is 65° at night and 70° at 7 AM for the Morning period. The building temperature is 65°, a difference of 5°. Allowing 5 minutes per °F rise, the thermostat will begin the system at 6:35 AM to reach 70° at 7 AM.

Page 11