Advanced Installer Configuration Menu
Thermostat Setup
Furnace User Menus (Cont.)
Unit Info
Parameter |
|
| Indications |
| Comments | ||
|
|
|
| ||||
Model Number | Unit Model Number | ||||||
Serial Number | XXXXXXXXXXXXXXXXXXX | Unit Serial Number (Not available if | |||||
|
|
|
|
|
| control is replaced) | |
|
|
|
|
| |||
Software Vers | XXXXXX |
|
| Control Software Version | |||
|
|
|
|
|
|
|
|
Setup |
|
|
|
|
|
|
|
Parameter |
| Options |
|
|
| Comments | |
|
|
|
| ||||
Heat Rise Adjust | 55F, 65F |
| Change airflow to adjust heat temperature rise | ||||
|
|
| |||||
Min Heat Adj % | Selectable Airflow Adjustments at 40% Firing Rate | ||||||
Max Heat Adj % | Selectable Airflow Adjustments at 100% Firing Rate | ||||||
|
|
|
| ||||
Supply Air Sens | On, Off |
| Factory default is On, if Sensor is not installed | ||||
|
|
|
|
| turn Off |
|
|
Reset All Dflts | No, Yes |
| Resets the Furnace to the Factory Default | ||||
|
|
|
|
| Configuration by selecting Yes | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Dipswitch* |
|
|
|
|
|
|
|
Dip Switch |
|
|
| Indications |
| Comments | |
|
|
|
|
|
|
| |
Cool Airflow |
|
| XXXXCFM |
| Airflow Dipswitch Settings | ||
|
|
|
|
|
|
| |
Heat Rise |
|
| Nom, Nom+10 |
| Heat Rise Airflow Settings | ||
|
|
|
|
|
|
| |
Hi Heat Adj |
|
|
| High Heat Airflow Settings | |||
|
|
|
|
|
|
| |
Lo Heat Adj |
|
|
| Low Heat Airflow Settings | |||
|
|
|
|
|
|
|
|
Fan Spd Select |
|
| Lo, Hi |
|
|
| Fan Speed Settings |
|
|
|
|
|
|
| |
|
|
| Heat Pump AC Airflow Settings | ||||
|
|
|
|
|
|
|
|
| On, Off |
|
|
| Dehumidification Settings | ||
|
|
|
|
|
|
| |
Test Mode |
|
| Off, 40% (70%), 100% |
| Test Mode Settings | ||
|
|
|
|
|
|
| |
AC HP Stg Mult |
|
| NA, 50%, 75% |
| Heat Pump AC Stage Multiplier | ||
|
|
|
|
|
|
|
|
*Dipswitch status is not required when the system is set up for
1
2
1
2
1
2
Select continuous FAN speed.
Default is Medium. It can be set to High, Medium or Low. In High, the fan will run at the highest speed when FAN key is selected to On. In high, the fan speed will be at high speed, in medium the fan speed will be approximately 60% of high, and in low the fan speed will be approximately 30% of high.
Select program days per week.
Scrolling message will show “PROGRAM TYPE”. Default is 7 Days to indicate individual day programming. It can be changed to 0 Days to indicate no programs will be run. When set for 7 Days, the thermostat will follow the factory program or the program that you entered.
Select Energy Management Recovery.
Scrolling Message will show “ENERGY MANAGEMENT RECOVERY”. (Will not appear if Program days per week is set to 0 Days.) When selected On, the thermostat will begin heating or cooling early to have the temperature reach the program setpoint at the program period start time.
Example: The heating program is 65° at night and 70° at 7 AM for the Morning period. The building temperature is 65°, a difference of 5°. Allowing 5 minutes per °F rise, the thermostat will begin the system at 6:35 AM to reach 70° at 7 AM.