Thermostat Setup
| Select continuous backlight. Scrolling | |
| message will show “BACKLIGHT”. | |
1 | When bL is selected On the backlight | |
will be on continuously. Selecting bL | ||
2 | ||
| OFF will allow the backlight to turn on | |
| momentarily when any key is touched. | |
| If system power is off and thermostat is | |
| operating on battery only, and bL is On, | |
| bL will turn the backlight on momentarily | |
| when a key is touched. | |
| Select temperature offset. Scrolling | |
| message will show “TEMPERATURE | |
1 | ADJUSTMENT”. Your thermostat was | |
accurately calibrated at the factory, | ||
2 |
however this option allows you to change the display temperature to match your previous thermostat if you prefer. Default is 0° with current temperature. Adjustment can be made from 5° Lo to 5° HI to change the displayed temperature.
Touch Run Schedule at any time to exit the Menu and return to Home Screen Display.
Advanced Installer Configuration Menu
Furnace User Menus (Cont.)
2 Week History (2 WK HIST)
Parameter |
| Indications |
| Comments | ||
2wk Lo HT Hrs |
| XXX |
|
| 2 Weeks Low Heat Hours of Operation | |
2wk Lo HT Cycls |
| XXXX |
|
| 2 Weeks Low Heat Cycles | |
|
|
|
|
|
| |
2wk Hi HT Hrs |
| XXX |
|
| 2 Weeks High Heat Hours of Operation | |
2wk Hi HT Cycls |
| XXXX |
|
| 2 Weeks High Heat Cycles | |
|
|
|
|
|
| |
2wk Y1 Hrs |
| XXX |
|
| 2 Week First Stage Cooling/Heat Pump Hours | |
|
|
|
|
| of Operation | |
2wk Y1 Cycles |
| XXXX |
|
| 2 Week First Stage Cooling/Heat Pump Cycles | |
|
|
|
|
|
| |
2wk Y2 Hrs |
| XXX |
|
| 2 Week Second Stage Cooling/Heat Pump | |
|
|
|
|
| Hours of Operation | |
2wk Y2 Cycles |
| XXXX |
|
| 2 Week Second Stage Cooling/Heat Pump Cycles | |
|
|
|
|
|
| |
2wk G Hrs |
| XXX |
|
| 2 Week Indoor Blower Hours of Operation | |
2wk G Cycles |
| XXXX |
|
| 2 Week Indoor Blower Cycles | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Life History (LIFE HIST) |
|
|
|
| ||
Parameter |
| Indications |
|
| Comments | |
|
|
|
|
|
|
|
Total Days Pwrd | XXXX |
| Total number of days control has been powered | |||
|
|
|
|
|
|
|
Lo HT Hrs | XXXXXX |
| Low Heat Hours of Operation | |||
Lo HT Cycles | XXXXXX |
| Low Heat Cycles | |||
|
|
|
|
|
|
|
Hi HT Hrs | XXXXXX |
| High Heat Hours of Operation | |||
Hi HT Cycles | XXXXXX |
| High Heat Cycles | |||
|
|
|
|
|
|
|
Y1 Hrs | XXXXXX |
| First Stage Cooling/Heat Pump Hours of Operation | |||
Y1 Cycles | XXXXXX |
| First Stage Cooling/Heat Pump Cycles | |||
Y2 Hrs | XXXXXX |
| Second Stage Cooling/Heat Pump Hours of | |||
|
|
|
| Operation |
| |
Y2 Cycles | XXXXXX |
| Second Stage Cooling/Heat Pump Cycles | |||
G Hrs | XXXXXX |
| Indoor Blower Hours of Operation | |||
|
|
|
|
| ||
Fault History (FAULT HIST) |
| |||||
Fault Code | Fault Occurred | Comments | ||||
|
|
|
|
| ||
XXXXXXXXXXXXXXX | Days XX | Displays up to 6 Faults; Days (XX) | ||||
|
|
|
|
|
| indicates how many days ago the fault |
|
|
|
|
|
| occurred |
|
|
|
|
|
| |
Clear Faults |
|
| No, Yes |
|