Furnace User Menus

Advanced Installer Configuration Menu

Thermostat Setup

Furnace User Menus

Status I

Parameter

Indications

 

Comments

 

 

 

Main Limit

Closed, Open

Main Limit Control Status

 

 

 

MRLC Input

Closed, Open

Main Reset Limit Control Status

 

 

 

HALC Input

Closed, Open

Heat Assist Limit Control Status

 

 

 

IDM Output

Off, Lo, Hi

Inducer Output Status

 

 

 

Furn Lo Pr Sw

Closed, Open

Furnace Low Pressure Switch Status

 

 

 

Furn Hi Pr Sw

Closed, Open

Furnace High Pressure Switch Status

 

 

 

Gas VLV Prcnt %

XXX%, Off

Mod Gas Valve % Open

 

 

 

Gas VLV Relay

Lo, Hi, On, Off

Gas Valve Control Output Status

 

 

 

Flame

Off, Marginal, Good,

Status of Flame Sensor

 

Unexpected

 

 

 

 

 

Blower CFM

CFM XXXX

Furnace Blower CFM

 

 

 

 

 

 

 

 

Status 2

 

 

 

Parameter

Indications

 

Comments

 

 

 

 

Mode

Mod Heat, Lo Heat, Hi Heat,

 

Indicates Operating Mode of System

 

AC1, AC2, Fan Only, Off,

 

 

 

HP1, HP2

 

 

 

 

 

 

Motor Mfgr

Regblt, Emerson

 

Blower Motor Manufacturer

 

 

 

 

Motor RPM

RPM

 

Blower Motor RPM

 

 

 

 

Maximum CFM

CFM XXXX

 

Maximum CFM Blower Provides

 

 

 

 

Blower CFM

CFM XXXX

 

Displays Current Operating CFM

 

 

 

 

Temp Rise

NA, XXXF

 

Difference between the Supply and

 

 

 

Return Air Temperature

 

 

 

 

Return Temp

XXXF, FLT

 

Displays Return Air Temp (if installed)

 

 

 

 

Supply Temp

NA, (If disabled), XXXF, FLT

 

Displays Supply Air Temp (if installed

 

 

 

and enabled in setup)

 

 

 

 

HUM Output

On, Off

 

Humidifier Output Relay Status

 

 

 

 

EAC Output

On, Off

 

Electronic Air Cleaner Output Relay

 

 

 

Status

 

 

 

 

1

2

1

2

1

2

Select temperature display as

Fahrenheit or Celsius. Scrolling message will show “SELECT TEMPERATURE DISPLAY”. This option selects the temperature display as °F or °C.

Select beeper (audio prompt) Default is On for the beeper to indicate a touch key selection. It can be changed to OFF.

Select air filter maintenance

reminder. Scrolling message will show “AIR FILTER MAINTENANCE”. Default is OFF. It can be changed to a setting from 25 to 1975 hours in increments of 25 hours to select the amount of time for the reminder. Consult your contractor for the hours and type of filter. Setting of 225 hours is typically 3 months of run time.

When the system has run for the selected length of time, the scrolling message area will show “CHANGE FILTER” to indicate maintenance is

required.