Advanced Installer Configuration Menu
Thermostat Setup
Furnace User Menus
Status I
Parameter | Indications |
| Comments |
|
|
| |
Main Limit | Closed, Open | Main Limit Control Status | |
|
|
| |
MRLC Input | Closed, Open | Main Reset Limit Control Status | |
|
|
| |
HALC Input | Closed, Open | Heat Assist Limit Control Status | |
|
|
| |
IDM Output | Off, Lo, Hi | Inducer Output Status | |
|
|
| |
Furn Lo Pr Sw | Closed, Open | Furnace Low Pressure Switch Status | |
|
|
| |
Furn Hi Pr Sw | Closed, Open | Furnace High Pressure Switch Status | |
|
|
| |
Gas VLV Prcnt % | XXX%, Off | Mod Gas Valve % Open | |
|
|
| |
Gas VLV Relay | Lo, Hi, On, Off | Gas Valve Control Output Status | |
|
|
| |
Flame | Off, Marginal, Good, | Status of Flame Sensor | |
| Unexpected |
|
|
|
|
| |
Blower CFM | CFM XXXX | Furnace Blower CFM | |
|
|
|
|
|
|
|
|
Status 2 |
|
|
|
Parameter | Indications |
| Comments |
|
|
|
|
Mode | Mod Heat, Lo Heat, Hi Heat, |
| Indicates Operating Mode of System |
| AC1, AC2, Fan Only, Off, |
|
|
| HP1, HP2 |
|
|
|
|
|
|
Motor Mfgr | Regblt, Emerson |
| Blower Motor Manufacturer |
|
|
|
|
Motor RPM | RPM |
| Blower Motor RPM |
|
|
|
|
Maximum CFM | CFM XXXX |
| Maximum CFM Blower Provides |
|
|
|
|
Blower CFM | CFM XXXX |
| Displays Current Operating CFM |
|
|
|
|
Temp Rise | NA, XXXF |
| Difference between the Supply and |
|
|
| Return Air Temperature |
|
|
|
|
Return Temp | XXXF, FLT |
| Displays Return Air Temp (if installed) |
|
|
|
|
Supply Temp | NA, (If disabled), XXXF, FLT |
| Displays Supply Air Temp (if installed |
|
|
| and enabled in setup) |
|
|
|
|
HUM Output | On, Off |
| Humidifier Output Relay Status |
|
|
|
|
EAC Output | On, Off |
| Electronic Air Cleaner Output Relay |
|
|
| Status |
|
|
|
|
1
2
1
2
1
2
Select temperature display as
Fahrenheit or Celsius. Scrolling message will show “SELECT TEMPERATURE DISPLAY”. This option selects the temperature display as °F or °C.
Select beeper (audio prompt) Default is On for the beeper to indicate a touch key selection. It can be changed to OFF.
Select air filter maintenance
reminder. Scrolling message will show “AIR FILTER MAINTENANCE”. Default is OFF. It can be changed to a setting from 25 to 1975 hours in increments of 25 hours to select the amount of time for the reminder. Consult your contractor for the hours and type of filter. Setting of 225 hours is typically 3 months of run time.
When the system has run for the selected length of time, the scrolling message area will show “CHANGE FILTER” to indicate maintenance is
required.