System Fault Codes

System Fault Codes

Display code

Diagnostic Description

1Long Run Time

2System Pressure Trip

3Short Cycling

4 (L4)

Locked Rotor

5 (L5)

Open Circuit

6 (L6)

Open Start Circuit

 

 

7 (L7)

Open Run Circuit

9

Low Secondary Voltage

11Failed ignition

12Low flame sense current

13Flame lost after established

14Flame present with gas valve off

21 (L21)

Low Pressure Switch Trip

22Main limit switch open.

23Auxiliary limit switch open

26Line Neutral Reversed

27Check Line Voltage

28High Line Voltage

29 (L29)

High Pressure Switch Trip

30

Fuse Open

33

MRLC Open

44Low pressure switch closed, inducer off

45Low pressure switch open, inducer on high speed

46Low pressure switch open, inducer on low speed

55

High pressure switch closed, inducer off

57

High pressure switch open, inducer on high speed

60Blower Fault Run

61Blower Fault No Run

66

RPM out of range (over 1200 RPM)

68

No Blower Communication

77Servo circuit open

78Servo control fault

79No Gas Valve Feedback

80Low Airflow

Table of Contents

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Battery Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Quick Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Installing Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Initial Power Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Thermostat Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Set Current Time and Day . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Choose the System Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Energy Saving Factory Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Set Up Thermostat Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Using the Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Advanced Installer Configuration

Menu/Service Information . . . . . . . . . . . . . . . . . . . . . . . . 19

Entering and Navigating the Advanced Installer

Configuration Menu/Service Information . . . . . . . . . . . . . . . . . . . . 19

Equipment User Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Thermostat User Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Furnace User Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Air Handler User Menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Heat Pump User Menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Air Conditioner User Menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Page 3
Image 3
White Rodgers HC-TST501CMMS manual System Fault Codes, Table of Contents, Advanced Installer Configuration