Initial Power-Up
Power Up
Turn on AC power to the system. The thermostat will automatically identify the communicating components installed.
Messages at Thermostat
During power up, the thermostat will scroll the word “SEARCHING” in the message area, indicating that the system is looking for components (Air Handler, Furnace, Heat Pump, Air Conditioner) on the Climate Talk network. Once the components are identified the message display will indicate the components found. Confirmation will be given in the message area that the equipment has been found with the message
(equipment) FOUND.
Note: If the thermostat display continuously shows “SEARCHING”, check the wiring to the thermostat.
Communications Systems
The thermostat will recognize the system devices that are connected and the capacities to set the system up to the operating settings. The system has additional flexibility which allows for the customization of certain parameters.
|
| Advanced Installer Configuration Menu | ||
Heat Pump User Menus (Cont.) | ||||
|
|
|
|
|
Cool Setup |
|
|
|
|
Parameter | Options |
| Comments |
|
|
|
|
|
|
AC Profile | A, B, C, D |
| Selectable Airflow Profiles (see Heat Pump |
|
|
|
| Installer Guide) |
|
|
|
|
|
|
Cool Air Adj % |
| Selectable Cooling Airflow Adjustments |
| |
|
|
|
|
|
On Demand | On, Off |
| Select Blower Operation on based on |
|
Dehum |
|
| humidity |
|
|
|
|
|
|
Reset All Dflts | No, Yes |
| Resets the Heat Pump to the Factory |
|
|
|
| Default Configuration by selecting Yes |
|
|
|
|
|
|
|
|
|
|
|
Heat Setup |
|
|
|
|
Parameter | Options |
| Comments |
|
|
|
|
|
|
HP Profile | A, B, C, D, |
| Selectable Airflow Profiles (See Heat Pump |
|
|
|
| Installer Guide) |
|
|
|
|
|
|
Heat Air Adj % |
| Selectable Heat Pump Airflow Adjustments |
| |
|
|
|
|
|
Dfrost Cmpr Dly | 0, 5, |
| Selectable Compressor Delay during |
|
|
|
| defrost |
|
|
|
|
|
|
Reset All Dflts | No, Yes |
| Resets the Heat Pump to the Factory |
|
|
|
| Default Configuration by selecting Yes |
|
|
|
|
|
|
HP Staging | On, Off |
| For |
|
|
| Default is On. This allows Low/High stages |
| |
Only) |
|
| of capacities. To only allow High capacity in |
|
|
|
| Heat Pump Mode select Off |
|
|
|
|
|
|