White Rodgers HC-TST501CMMS Set Up Thermostat Options, Air Handler User Menus, Thermostat Setup

Models: HC-TST501CMMS

1 18
Download 18 pages 1.72 Kb
Page 10
Image 10
Set Up Thermostat Options

Thermostat Setup

Set Up Thermostat Options

The Thermostat has options that can be selected and adjusted. These options are in the Thermostat Options Configuration Menu. On the Home Screen Display, touch the Menu key to display additional key choices.

Touch and hold the Installer Config key for 3 seconds. This displays the first menu item as shown in the next step. TouchAir Handler User Menus or Manual background to change a menu option. TouchManual backgroundto advance to the next menu item orManual backgroundto return to the previous menu item. Touch Run Schedule at any time to exit the menu and return to Home Screen Display.

 

Select On Demand Dehumidification

 

(ODD) setting. Default is OFF. It can

 

be set in the range of 40 to 94%. Above

1

94% is the OFF setting. Ideally, the

2

indoor humidity should be set in the

 

range of 40 to 60%.

When On Demand Dehumidification is selected, the thermostat will indicate the current humidity on the home screen. The display will show RH with the humidity %. If the current humidity is above the selected setting, the thermostat will send an On Demand Dehumidification request.

On Demand Dehumidification improves the comfort level in your home by reducing the humidity level. This is accomplished by slowing down the system fan speed and lengthening the run time. The humidity setting may not be reached before the call for cool has been satisfied as the system priority is to maintain the temperature in the home.

Advanced Installer Configuration Menu

Air Handler User Menus

Status

Parameter

Indications

Comments

 

 

 

Auxiliary Heat

On, Off

Auxiliary Heat Status

 

 

 

Blower CFM

CFMXXXX

Air Handler Blower CFM

 

 

 

Motor Mfgr

Rgblt, Emerson

Blower Motor Manufacturer

 

 

 

Motor RPM

RPMXXXX

Blower Motor RPM

 

 

 

Maximum CFM

CFMXXXX

Maximum CFM of the Air Handler

 

 

 

Temp Rise

NA, XXXF, FLT

Difference Between the Supply and

 

 

Return Air Temperature (NA if either

 

 

sensor is disabled)

 

 

 

Return Temp

NA (if disabled),

Displays Return Air Temperature

 

XXXF, FLT

(if installed and enabled in Setup)

 

 

 

Supply Temp

NA (if disabled),

Displays Supply Air Temperature

 

XXXF, FLT

(if installed and enabled in Setup)

 

 

 

 

 

 

2 Week History (2 WK HIST)

 

Parameter

Indications

Comments

 

 

 

2wk AuxHT Hrs

XXX

2 Week Auxiliary Heat Hours of Operation

 

 

 

2wk AuxHT Cycls

XXXX

2 Week Auxiliary Heat Cycles

 

 

 

2wk G Hrs

XXX

2 Week Blower Hours of Operation

 

 

 

2wk G Cycles

XXXX

2 Week Blower Cycles

 

 

 

 

 

Life History (LIFE HIST)

 

Parameter

Indications

Comments

 

 

 

Total Days Pwrd

XXXX

Total number of days control has been

 

 

powered

 

 

 

Aux HT Hrs

XXXXXX

Auxiliary Heat Hours of Operation

 

 

 

Aux HT Cycles

XXXXXX

Auxiliary Heat Cycles

 

 

 

G Hrs

XXXXXX

Continuous Fan Hours of Operation

 

 

 

G Cycles

XXXXXX

Continuous Fan Cycles

 

 

 