Select UV lamp maintenance

Thermostat Setup

Advanced Installer Configuration Menu

1

2

1

2

Select UV lamp maintenance

reminder. Scrolling message will show “UV LAMP MAINTENANCE”. Default is OFF. It can be changed to a setting from 25 to 1975 days in increments of 25 days to select the amount of time for the reminder. Setting of 350 days is an annual reminder.

Based on this setting, the scrolling message area will show “CHANGE UV LAMP” to indicate maintenance is required.

Select humidifier pad maintenance

reminder. Scrolling message will show

HUMIDIFIER PAD MAINTENANCE”. Default is OFF. It can be changed to a setting from 25 to 1975 hours in increments of 25 hours to select the amount of time for the reminder. Setting of 100 hours is typically 6 months of run time.

Based on this setting, the scrolling message area will show “CHANGE HUMIDIFIER PAD” to indicate maintenance is required.

Thermostat User Menus

 

Status

 

 

Parameter

Indications

Comments

 

 

 

Configuration

HP - Heat Pump

Indication in center of screen shows the

 

DF - Dual Fuel

configuration of the thermostat based on the

 

GH - Gas Heat

equipment connected.

 

ES - Electric System

The type of system with the number of stages

 

AC - Air Conditioner

will be displayed above the or . Additional

 

FN - Fan

system types and stages can be viewed by

 

EH - Electric Heat

pressing or .

--- Furnace and Air Conditioner

Setup

Parameter

Options

Comments

 

 

 

Outdoor

bL, On, OFF

bL – (7 Days Programming only) Factory default is

Temperature

 

(bLink), alternates time display between time and

Display

 

outdoor temperature.

 

 

On – (0 Days Programming default) The outdoor

 

 

temperature is displayed continuously on the time

 

 

display.

 

 

OFF – Only Time is displayed.

 

 

 

Heat Pump

OFF, 5° to 50°F

Available only for air handler with heat pump

Disable (HP)

 

systems. Disables heat pump and turns on electric

 

 

heat below the selected outdoor temperature.

 

 

 

Dual Fuel

OFF, 5° to 50°F

Available only for furnace with heat pump systems

Disable (DF)

 

(dual fuel systems). Switches from heat pump to

 

 

fossil fuel equipment (furnace) below the selected

 

 

temperature.

 

 

 

Air Handler

OFF, Heat Pump

Available only for air handler with heat pump

Lockout

Disable setting to

systems. Disables electric heat above the selected

Temperature

95°F

outdoor temperature. OFF defaults to 50°F.

(AH)

 

 

 

 

 

<equipment>_

No, Yes

Steps the selected equipment through its

Test

 

sequential mode of operation.

 

 

 

Reset System

No, Yes

This will reset ALL of the communicating system

 

 

components to their factory set values.

 

 

 

Page 14