White Rodgers HC-TST501CMMS manual Air Handler User Menus Cont, Energy Saving Factory Pre-Program

Models: HC-TST501CMMS

1 18
Download 18 pages 1.72 Kb
Page 9
Image 9
Air Handler User Menus (Cont.)

Advanced Installer Configuration Menu

Air Handler User Menus (Cont.)

Fault History (FAULT HIST)

Fault Code

 

Fault Occurred

 

Comments

 

 

 

 

XXXXXXXXXXXXXXX

Days XX

 

Displays up to 6 Faults; Days (XX)

 

 

 

 

indicates how many days ago the fault

 

 

 

 

occurred

 

 

 

 

 

 

Clear Faults

 

No, Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Info

 

 

 

 

 

Parameter

 

Indications

Comments

 

 

 

Model Number

XXXX-XXXXXXXXXXXXXXXX

Unit Model Number

 

 

 

Serial Number

XXXXXXXXXXXXXXXXXXX

Unit Serial Number (not available

 

 

 

 

 

if control is replaced)

 

 

 

 

 

Software Vers

XXXXXX

 

 

Control Software Version

 

 

 

 

 

 

 

 

 

 

 

 

Setup

 

 

 

 

 

Parameter

 

Options

 

 

Comments

 

 

 

 

 

Return Air Sens

Off, On

If Return Air Sensor is field installed, turn On.

 

 

 

Factory Default is Off

 

 

 

 

 

Supply Air Sens

Off, On

If Supply Air Sensor is field installed, turn On.

 

 

 

Factory Default is Off

 

 

 

 

 

Reset All Dflts

No, Yes

Resets the Air Handler to the Factory Default

 

 

 

Configuration by selecting Yes

 

 

 

 

 

 

 

 

 

 

 

 

Dipswitch*

 

 

 

 

 

Dip Switch

 

Indications

Comments

 

 

 

 

 

 

Cool Airflow

XXXXCFM

 

 

View Airflow Dipswitches

 

 

 

 

 

 

HT Pump Airflow

XXXXCFM

 

 

View Heat Pump Airflow Dipswitch

 

 

 

 

 

Settings

 

 

 

 

 

 

Cool Air Adj

-10%, 0%, 10%

 

 

View Airflow Trim Settings

 

 

 

 

 

 

On-Demand

On, Off

 

 

Activate Dehumidification Feature

Dehum

 

 

 

 

 

 

 

 

 

 

 

*Dipswitch status is not required when the system is set up for 4-wire communications. It is only displayed when a conventional 24V thermostat input is active.

Thermostat Setup

Choose the System Setting (Cool, Off, Heat, Em, Auto)

Touch the SYSTEM key to select:

Cool: Thermostat controls only the cooling system.

Off: Heating and Cooling systems are off.

Heat: Thermostat controls only the heating system.

Em: Thermostat controls emergency heating only.

Auto: Auto Changeover is used where both heating and cooling may be required during the same day. Auto allows the thermostat to automatically select heating or cooling depending on the indoor temperature and the selected heat and cool setpoints. This thermostat will not allow you to program a conflict between Heating and Cooling setpoints. For setting Auto mode see page 17.

Energy Saving Factory Pre-Program

This touchscreen thermostat is programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your customer’s needs, simply touch the Run Schedule key.

Factory Pre-Programmed heating and cooling schedule for all days of the week

 

Wake Up

Leave For Work

Return Home

Go To Bed

 

(Morning)

(Day)

(Evening)

(Night)

 

 

 

 

 

 

 

 

 

Heating Program

6:00 AM

70°F

8:00 AM

62°F

5:00 PM

70°F

10:00 PM

62°F

 

 

 

 

 

 

 

 

 

Cooling Program

6:00 AM

75°F

8:00 AM

83°F

5:00 PM

75°F

10:00 PM

78°F

 

 

 

 

 

 

 

 

 

Instructions for changing the programming are in the Homeowner User Guide.

Page 9
Image 9
White Rodgers HC-TST501CMMS manual Air Handler User Menus Cont, Energy Saving Factory Pre-Program, Thermostat Setup