A C C E S S O R I E S

Optional acces- sories are available through your Wolf dealer. To obtain local dealer information, visit the Locator section of our website, wolfappliance.com.

W O L F PRO WALL VENTILATION H O O D S

IN - LINE A N D REMOTE B L O W E R S

B L O W E R I N S TA L L AT I O N

IMPORTANT NOTE: Refer to the specific installation instructions provided with each blower for additional mounting instructions.

Locate the blower so that the length of the duct run and number of elbows and transitions are kept to a minimum. Wolf recommends the maximum linear duct run be no greater than 50' (15 m).

If possible, remote blowers should be located between wall studs or roof rafters. Avoid pipes, wires or other ductwork that may be running through the wall.

Be sure that there is enough space for any transitions that may be needed between the blower and the connecting ductwork. For best performance, locate transitions nearest the blower.

Refer to the illustrations below and on the following page for overall dimensions of Wolf in-line and remote blowers. Also refer to the specific installation instructions provided with each remote blower to verify cut-out dimen- sions.

 

243/8"

 

(619)

113/4"

 

(298)

 

181/2"

 

(470)

 

 

41/2"

 

(114)

211/2"

121/4"

(546)

 

(311)

 

 

247/8"

 

 

(632)

18"

12"

 

(457)

 

 

(305)

 

 

 

8"

 

 

(203)

 

22"

18"

 

(559)

(457)

Dimensions for BLOWER-60IL

Dimensions for BLOWER-110IL

18

Page 18
Image 18
Wolf W302210I installation instructions Line a N D Remote B L O W E R S, O W E R I N S Ta L L At I O N