W1770 21" Bandsaw w/Foot Brake

 

 

 

 

 

Wiring Diagram

 

 

 

 

 

 

L1

 

 

 

 

 

 

 

SHOCK HAZARD!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L2

 

 

 

 

Disconnect power before servicing electrical

POWER

 

 

 

 

 

 

 

 

 

parts. Touching electrified parts will result in

SUPPLY

 

 

 

 

Ground

 

 

 

 

severe burns, electrocution, or death.

 

JUNCTION

 

 

 

 

 

 

 

 

Ground

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLOCK

 

 

 

 

 

 

 

 

 

L1 Hot

 

 

 

(Figure 78,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X

G

 

 

Page 55)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y

 

220 VAC

 

 

 

 

 

 

 

 

 

 

 

L6-30 PLUG

 

 

 

 

 

 

 

 

 

 

L2 Hot

 

MAG

 

 

 

 

 

 

 

 

 

 

(as recommended)

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

 

 

 

 

 

 

 

 

 

LIMIT SWITCH (NC)

 

 

 

ASSEMBLY

 

 

 

Ground

 

 

 

 

 

 

 

SDE MPE-18

 

 

 

 

 

 

See Figure 80, Page 55

 

 

 

 

 

 

 

 

 

 

11

12

(Figure 82,

 

A

 

 

 

 

 

 

 

 

 

 

 

Page 55)

 

 

 

 

 

 

 

CONTROL PANEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(viewed from behind)

 

23

24

 

 

L1/1

L2/3

L3/5

NO13

 

 

 

See Figure 79, Page 55

 

 

 

 

CONTACTOR

 

 

SDE

NC15

 

 

Ground

22

21

 

 

 

 

 

 

 

MA-18

SDE

 

 

 

 

PWR

 

 

 

 

 

 

 

220V

NC16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14 13

 

 

 

 

 

T1/2

T2/4

T3/6

NO14

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

SDE RA-30

RESET

 

 

 

 

 

 

 

 

 

 

 

 

18-26

 

 

22

21

 

 

 

 

THERMAL

 

 

 

 

 

 

 

 

 

 

 

1/2

3/4

5/6

 

 

 

 

 

ON

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14 13

 

 

 

 

 

 

 

 

96

 

98

 

 

 

 

 

 

 

 

 

 

 

 

 

95

 

 

 

 

 

 

 

22

21

 

220V

 

OFF

 

 

 

 

MOTOR

Start

14 13

 

(Figure 81,

 

 

Capacitor

 

 

Page 55)

400MFD

 

 

 

250VAC

 

SERVICE

Ground

Run

NC

Capacitor

FOOT BRAKE

 

45MFD

 

350VAC

See Figure 80,

 

 

 

 

Page 55

 

 

 

-56-

Figure 83. Capacitors.

Page 58
Image 58
Woodstock W1770 manual Wiring Diagram, See Figure