ELECTRICAL

Model W1823 (Mfg. Since 9/10)

ELECTRICAL

Circuit Requirements

This machine must be connected to the correct size and type of power supply circuit, or fire or electrical damage may occur. Read through this section to determine if

an adequate power supply circuit is available for this machine. If a correct circuit is not available, you must have a qualified electrician install one before you can operate the machine.

A power supply circuit includes all electrical equipment between the main breaker box or fuse panel in the building and the incoming power connections at the machine. The power supply circuit used for this machine must be sized to safely handle the full-load current drawn from the machine for an extended period of time.

Full-Load Current Rating

The full-load current rating is the amperage a machine draws at 100% of the rated output power. On machines with multiple motors, this is the amperage drawn by the largest motor or sum of all motors and electrical devices that might operate at one time during normal operations.

Full-Load Current Rating at 110V

15

Amps

Full-Load Current Rating at 220V

7.5

Amps

K_\ dXZ_`e\ dljk Y\ gifg\icp j\k lg Y\]fi\ `k `j jX]\ kf fg\iXk\% ;F EFK Zfee\Zk k_`j dXZ_`e\ kf k_\ gfn\i jfliZ\ lek`c `ejkilZk\[ kf [f cXk\i `e k_`jdXelXc%

@eZfii\Zkcp n`i`e^ fi ^ifle[`e^ k_`j dXZ_`e\ZXeZXlj\\c\ZkifZlk`fe#]`i\# fidXZ_`e\[XdX^\%Kfi\[lZ\k_`ji`jb# fecp X hlXc`]`\[ \c\Zki`Z`Xe fi j\im`Z\ g\ijfee\c j_flc[ [f Xep i\hl`i\[ \c\Zki`ZXcnfib]fik_`jdXZ_`e\%

ELECTRICAL

Circuit Requirements for 110V (Prewired)

This machine is prewired to operate on a 110V power supply circuit that has a verified ground and meets the following requirements:

Circuit Type

110V/120V, 60 Hz, Single-Phase

Circuit Size

20 Amps

Plug/Receptacle

NEMA 5-15

Circuit Requirements for 220V

This machine can be converted to operate on a 220V power supply (details about voltage conversion can be found later in this manual). The 220V power supply circuit must have a verified ground and meet the requirements that follow:

Circuit Type

220V/240V, 60 Hz, Single-Phase

Circuit Size

15 Amps

Plug/Receptacle

NEMA 6-15

EFK@:<

K_\ Z`iZl`k i\hl`i\d\ekj c`jk\[ `e k_`j dXelXc Xggcp kf X [\[`ZXk\[ Z`iZl`kÇ n_\i\fecpfe\dXZ_`e\n`ccY\ilee`e^ Xk X k`d\% @] k_`j dXZ_`e\ n`cc Y\ Zfee\Zk\[ kf X j_Xi\[ Z`iZl`k n_\i\ dlck`gc\ dXZ_`e\j n`cc Y\ ilee`e^ Xk k_\ jXd\ k`d\# Zfejlck X hlXc`]`\[ \c\Zki`Z`Xekf\ejli\k_Xkk_\Z`iZl`k`j gifg\icpj`q\[]fijX]\fg\iXk`fe%