Woodstock W1823 manual Grounding Requirements, Extension Cords, For 110V Connection Prewired, 220V

Models: W1823

1 44
Download 44 pages 6.77 Kb
Page 12
Image 12
Grounding Requirements

Model W1823 (Mfg. Since 9/10)

ELECTRICAL

Grounding Requirements

In the event of certain types of malfunctions or breakdowns, grounding provides a path of least resistance for electric current to travel—in order to reduce the risk of electric shock.

Improper connection of the equipment-grounding wire will increase the risk of electric shock. The wire with green insulation (with/without yellow stripes) is the equipment- grounding wire. If repair or replacement of the power cord or plug is necessary, do not connect the equipment- grounding wire to a live (current carrying) terminal.

Check with a qualified electrician or service personnel if you do not understand these grounding requirements, or if you are in doubt about whether the tool is properly grounded. If you ever notice that a cord or plug is damaged or worn, disconnect it from power, and immediately replace it with a new one.

For 110V Connection (Prewired)

This machine is equipped with a power cord that has an equipment-grounding wire and NEMA 5-15 grounding plug. The plug must only be inserted into a matching receptacle (see =`^li\) that is properly installed and grounded in accordance with local codes and ordinances.

For 220V Connection (Must be Rewired)

A NEMA 6-15 plug has a grounding prong that must be attached to the equipment-grounding wire inside the included power cord. The plug must only be inserted into a matching receptacle (see =`^li\) that is properly installed and grounded in accordance with all local codes and ordinances.

Extension Cords

We do not recommend using an extension cord with this machine. Extension cords cause voltage drop, which may damage electrical components and shorten motor life.

Voltage drop increases with longer extension cords and the gauge smaller gauge sizes (higher gauge numbers indicate smaller sizes).

Any extension cord used with this machine must contain a ground wire, match the required plug and receptacle, and meet the following requirements:

Minimum Gauge Size at 110V

12 AWG

Minimum Gauge Size at 220V

14 AWG

Maximum Length (Shorter is Better)

50 ft.

 

-10-

K_\ dXZ_`e\ dljk Y\ gifg\icp j\k lg Y\]fi\ `k `j jX]\ kf fg\iXk\% ;F EFK Zfee\Zk k_`j dXZ_`e\ kf k_\ gfn\i jfliZ\ lek`c `ejkilZk\[ kf [f cXk\i `e k_`jdXelXc%

110V GROUNDED

5-15 RECEPTACLE Grounding Prong

5-15 PLUG

 

Neutral Hot

Figure 3. NEMA 5-20 plug & receptacle.

220V

GROUNDED

6-15 RECEPTACLE

Current Carrying Prongs

 

6-15 PLUG

Grounding Prong

Figure 4. NEMA 6-15 plug & receptacle.

;F EFK df[`]p k_\ gifm`[\[ gcl^ fi lj\ Xe X[Xgk\i `] k_\ gcl^ n`cc efk ]`k pfli i\Z\gkXZc\% K_`j `j Xe `e[`ZXk`fe k_Xk pfli gfn\i jlggcp Z`iZl`k [f\j d\\k k_\ i\hl`i\d\ekj ]fi k_\ dXZ_`e\2 _Xm\ Xe \c\Zki`Z`Xe `ejkXcck_\Zfii\Zkgfn\ijlggcpZ`iZl`k% @] k_\ dXZ_`e\ dljk Y\ i\Zfee\Zk\[ ]fi lj\ fe X [`]]\i\ek kpg\ f] \c\Zki`Z Z`iZl`k# k_\ i\Zfee\Zk`fe j_flc[ Y\ dX[\ Yp X hlXc`]`\[ \c\Zki`Z`Xe fi j\im`Z\ g\ijfee\c2 X]k\i i\Zfee\Zk`fe# k_\dXZ_`e\dljkZfdgcpn`k_XcccfZXc Zf[\jXe[fi[`eXeZ\j%

Page 12
Image 12
Woodstock W1823 Grounding Requirements, Extension Cords, For 110V Connection Prewired, For 220V Connection Must be Rewired