Model W1823 (Mfg. Since 9/10) |
|
|
6. Using the square port in the blower housing (see |
|
|
Figure 12) for access, fasten the magnetic switch |
|
|
bracket on the studs with (2) 5⁄16" flat washers and |
|
|
(2) |
|
|
7. With the help of another person, lift and position the |
| Magnetic |
dust collector upright, then lock the casters so the |
| Switch |
unit will not move during the rest of the assembly | Mounting | Bracket |
process. | Bolts |
|
| Figure 12. Magnetic switch installation. |
8.Have another person hold the cyclone funnel in- place against the intake barrel, and align the datum point labels, as shown in Figure 13, then clamp the cyclone funnel and the intake barrel together using the barrel clamp. To ensure a tight seal, make sure the clamp is tight when it overlaps, as shown in
Figure 13.
9.Connect the outlet port and its larger gasket to the filter canister with (6)
10.Have another person hold the canister filter in place while you fasten the outlet port and its smaller gasket to the blower housing with (8)
11.Reach inside the canister filter and rotate the cleaning flap so the flat on the filter cleaning rod faces outward.
12.Place the cleaning handle onto the shaft, align the flat and set screw, then tighten the set screw (see
Figure 14).
Overlap |
|
Intake Barrel | SETUP |
| |
Alignment |
|
Cyclone |
|
Funnel |
|
Figure 13. Cyclone funnel installation.
Outlet Port |
Set |