Model W1823 (Mfg. Since 9/10)

PROBLEM

 

POSSIBLE CAUSE

 

corrective action

Dust collector does not

1.

Dust collection drum is full.

1.

Empty collection drum.

adequately collect dust or

2.

Filter is dirty, drum is full.

2.

Clean filter, empty collection drum.

chips; poor performance.

3.

Dust collector is undersized for

3.

Use the correct size duct collector for the type of

 

 

the task.

 

machine.

 

4.

Ducting is at fault.

4.

Remove dust line from dust collector inlet and

 

 

 

 

unblock the restriction in the duct line.

 

5.

The dust collector is too far away

5.

Relocate the dust collector closer to the point of

 

 

from the point of suction, or there

 

suction, and rework ducting without sharp bends.

 

 

are too many sharp bends in the

 

Refer to Collection System, beginning on Page 20.

 

 

ducting.

 

 

 

6.

The lumber is wet and wood

6.

Process lumber with less than 20% moisture

 

 

chips are not flowing through the

 

content.

 

 

ducting smoothly.

 

 

 

7.

There is a leak in the ducting, or a

7.

Rework the ducting to eliminate all leaks. Close

 

 

series of small leaks, or too many

 

dust ports for lines not being used.

 

 

open ports.

 

 

 

8.

There are not enough open branch

8.

Open 1 or 2 more blast gates to different branch

 

 

lines at one time, thereby causing

 

lines to allow the velocity in the main line to

 

 

a velocity drop in the main line.

 

increase.

 

9.

The ducting and ports are

9.

Re-install correctly sized ducts and fittings, contact

 

 

incorrectly sized.

 

machine manufacture for larger port dust collection

 

 

 

 

shroud. Some machines have poor design for dust

 

 

 

 

collector use.

 

10.

The machine overall dust

10.

Use a dust collection nozzle on a stand.

 

 

collection design is inadequate.

 

 

 

11.

The dust collector is too small for

11.

Install a larger dust collector to power your dust

 

 

the dust collection system.

 

collection system.

 

 

 

 

 