POST Error Code

FRU/Action

 

 

 

111

1.

Reseat adapters

I/O channel parity error

2.

Any adapter

 

 

3.

Riser card

 

4.

System Board

 

 

 

114

1.

Adapter Memory

Adapter ROM error

2.

System Board

 

 

3.

Riser card

 

 

 

129

1.

Processor

Internal cache test error

2.

L2 Cache Memory

 

 

3.

System Board

 

 

 

135 Fan failure

1.

Fan

 

 

2.

System board

 

 

 

151

1.

System Board

System board failure

 

 

 

 

 

161

1.

Run Setup

Bad CMOS battery

2.

CMOS Backup Battery (see “Safety

 

 

 

information” on page 271)

 

3.

System Board

 

 

 

162

1.

Run Setup and verify Configuration

Configuration mismatch

2.

Had a device been added, removed,

 

 

 

changed location? If not, suspect that

 

 

device.

 

3.

Power-on external devices first, then

 

 

power-on computer

 

4.

CMOS Backup Battery (see “Safety

 

 

information” on page 271)

 

 

System Board

 

5.

System Board

 

 

 

163

1.

Time and Date Set

Date and Time Incorrect

2.

CMOS Backup Battery (see “Safety

 

 

 

information” on page 271)

 

3.

System Board

 

 

 

164

1.

Run Setup. Check System Summary

Memory Size Error

 

menu for memory size change. (See

 

 

 

 

“Setup Utility program” on page 24.)

 

2.

Run the Extended Memory Diagnostic

 

 

tests

 

 

 

166

1.

Run Flash Recovery using Boot Block.

Boot Block Check Sum Error

 

See “Flash recovery boot block jumper”

 

 

 

 

on page 267.

 

2.

System Board

 

 

 

167

1.

Run Setup. Check Stepping level for

No Processor BIOS Update Found

 

the BIOS level needed, then perform

 

 

 

 

the flash update.

 

2.

Processor

 

 

 

Chapter 7. Symptom-to-FRU Index 111

Page 117
Image 117