Diagnostic Error Code

FRU/Action

 

 

 

035-196-XXX

1.

Press F3 to review the log file

RAID interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

035-197-XXX

1.

Make sure the component that is called

RAID interface test warning

 

out is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

035-198-XXX

1.

If a component is called out, make sure

RAID interface test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problems

 

 

section

 

 

 

035-199-XXX

1.

Go to the Undetermined problems

RAID interface test failed, cause unknown

 

section

 

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

071-000-XXX

1.

No action

Audio port Interface Test Passed

 

 

 

 

 

071-00X-XXX

1.

Run Setup

071-01X-XXX

2.

Flash the system

071-02X-XXX

3.

System board

Audio port error

 

 

 

071-03X-XXX

1.

Speakers

Audio port failure

2.

Microphone

 

 

3.

Audio card, if installed

 

4.

System board

 

 

 

071-04X-XXX

1.

Run Setup

Audio port failure

2.

Audio card, if installed

 

 

3.

System board

 

 

 

071-195-XXX

1.

Information

Audio port Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

071-196-XXX

1.

Press F3 to review the log file

Audio port test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

071-197-XXX

1.

Make sure the component that is called

Audio port test warning

 

out is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

071-198-XXX

1.

If a component is called out, make sure

Audio port test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problems

 

 

section

 

 

 

Chapter 7. Symptom-to-FRU Index 101

Page 107
Image 107
IBM 8306, 8309, 8308 XXX Make sure the component that is called, XXX If a component is called out, make sure, XXX No action