POST Error Code

FRU/Action

 

 

 

225

1.

Unsupported Memory

 

 

 

 

229

1.

L2 Cache Memory

External cache test error

2.

System Board

 

 

 

 

262

1.

Run Setup. Check System Summary

POST detected a base memory or extended

 

menu for memory. (See “Setup Utility

memory type error

 

 

program” on page 24.)

 

 

 

2.

Run the Extended Memory Diagnostic

 

 

tests.

 

 

 

301 Keyboard Error

1.

Keyboard

 

 

2.

Keyboard Cable

 

3.

System Board

 

 

 

303

1.

Mouse

With an 8603 error

2.

Keyboard

 

 

3.

Keyboard Cable

 

4.

System Board

 

 

 

303

1.

Keyboard

With no 8603 error

2.

Keyboard Cable

 

 

3.

System Board

 

 

 

3XX

1.

Keyboard

Not listed above

2.

Keyboard Cable

 

 

3.

System Board

 

 

 

5XX

1.

Video Adapter (if installed)

 

 

2.

System Board

 

 

 

601

1.

Diskette Drive A

 

 

2.

Diskette Drive Cable

 

3.

System Board

 

4.

Riser card

 

 

 

602

1.

Bad Diskette?

 

 

2.

Verify Diskette and retry

 

 

 

604

1.

Run Setup and verify diskette

And able to run diagnostics

 

configuration settings

 

 

 

2.

Diskette Drive A/B

 

3.

Diskette Drive Cable

 

4.

System Board

 

5.

Riser card

 

 

 

605

1.

Diskette Drive

POST cannot unlock the diskette drive

2.

Diskette Drive Cable

 

 

3.

System Board

 

4.

Riser card

 

 

 

662 Configuration Change has occured

1.

Diskette drive configuration error or

 

 

 

wrong diskette drive type; run Setup

 

 

Configuration

 

 

 

Chapter 7. Symptom-to-FRU Index 113

Page 119
Image 119
IBM 8314 Run Setup. Check System Summary, Menu for memory. See Setup Utility, Mouse, Keyboard, Video Adapter if installed