Diagnostic Error Code

FRU/Action

 

 

 

000-197-XXX

1.

Make sure the component that is called

BIOS test warning

 

out is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

000-198-XXX

1.

If a component is called out, make sure

BIOS test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problems

 

 

section

 

 

 

000-199-XXX

1.

Go to the Undetermined problems

BIOS test failed, cause unknown

 

section

 

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

000-250-XXX

1.

Flash the system

BIOS APM failure

2.

System board

 

 

 

 

000-270-XXX

1.

Flash the system

BIOS ACPI failure

2.

System board

 

 

 

 

001-000-XXX

1.

No action

System Test Passed

 

 

 

 

 

001-00X-XXX

1.

System board

System Error

 

 

 

 

 

001-01X-XXX

1.

System board

System Error

 

 

 

 

 

001-024-XXX

1.

System board

System Addressing test failure

 

 

 

 

 

001-025-XXX

1.

Flash the system

System Checksum Value error

2.

System board

 

 

 

 

001-026-XXX

1.

Flash the system

System FLASH data error

2.

System board

 

 

 

 

001-027-XXX

1.

Run Setup

System Configuration/Setup error

2.

Flash the system

 

 

3.

System board

 

 

 

001-032-XXX

1.

System board

System Device Controller failure

 

 

 

 

 

001-034-XXX

1.

Reboot the system

System Device Buffer Allocation failure

2.

Flash the system

 

 

3.

Run memory test

 

4.

System board

 

 

 

001-035-XXX

1.

System board

System Device Reset condition detected

 

 

 

 

 

001-036-XXX

1.

System board

System Register error

 

 

 

 

 

90Hardware Maintenance Manual

Page 96
Image 96
IBM 8303, 8309, 8308, 8312, 8313, 8311, 8310, 8315, 8314, 8301, 8306, 8304, 8302, 8305 manual Hardware Maintenance Manual