Diagnostic Error Code

FRU/Action

 

 

 

014-001-XXX

1.

Remove external parallel device, if

Parallel port Presence

 

present

 

 

 

2. Run setup, enable port

 

3.

System board

 

 

 

014-002-XXX

1.

System board

014-003-XXX

 

 

Parallel port Timeout/Parity error

 

 

 

 

 

014-013-XXX

1.

System board

014-014-XXX

 

 

Parallel port Control Signal/Loopback test

 

 

failure

 

 

 

 

 

014-015-XXX

1.

Wrap plug

Parallel port External Loopback failure

2.

System board

 

 

 

 

014-027-XXX

1.

Run Setup, enable port

Parallel port Configuration/Setup error

2.

Flash the system

 

 

3.

System board

 

 

 

014-03X-XXX

1.

System board

014-04X-XXX

 

 

Parallel port failure

 

 

 

 

 

014-195-XXX

1.

Information

Parallel port Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

014-196-XXX

1.

Press F3 to review the log file

Parallel port test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

 

 

 

014-197-XXX

1.

Make sure the component that is called

Parallel port test warning

 

out is connected and/or enabled

 

 

 

2. Re-run test

 

3. Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

014-198-XXX

1.

If a component is called out, make sure

Parallel port test aborted

 

it is connected and/or enabled

 

 

 

2. Flash the system and re-test

 

3. Go to the Undetermined problems

 

 

section

 

 

 

014-199-XXX

1.

Go to the Undetermined problems

Parallel port test failed, cause unknown

 

section

 

 

 

2. Flash the system and re-test

 

3. Replace component under function test

 

 

 

014-2XX-XXX

1.

External parallel device

014-3XX-XXX

2.

System board

Parallel port failure

 

 

 

 

 

015-000-XXX

1.

No action

USB port Interface Test Passed

 

 

 

 

 

015-001-XXX

1.

Remove USB device(s) and re-test

USB port Presence

2.

System board

 

 

 

 

96Hardware Maintenance Manual