POST Error Code

FRU/Action

 

 

 

180X, 188X

1.

Run Setup and verify PCI/ISA

PCI configuration or resource error

 

configuration settings.

 

 

 

2.

If necessary, set ISA adapters to Not

 

 

available to allow PCI adapters to

 

 

properly configure.

 

3.

Remove any suspect ISA adapters.

 

4.

Rerun diagnostics.

 

5.

PCI Adapter

 

 

 

1962

1.

Press F1 to repeat boot sequence.

No operating system found

 

 

 

 

 

209X

1.

Diskette Drive

 

 

2.

Diskette Cable

 

 

 

20XX

1.

BSC Adapter

Not listed above

 

 

 

 

 

21XX

1.

SCSI Device

 

 

2.

16-bit AT Fast SCSU adapter

 

3.

Alternate BSC adapter

 

 

 

2401, 2402

1.

Display

If screen colors change

 

 

 

 

 

2401, 2402

1.

System Board

If screen colors are OK

2.

Display

 

 

 

 

2409

1.

Display

 

 

 

 

2410

1.

System Board

 

 

2.

Display

 

 

 

2462

1.

Check cable connections

Video memory configuration error

2.

Run Setup and verify video

 

 

 

configuration settings

 

3.

Video Memory Modules

 

4.

Video Adapter (if installed)

 

5.

System Board

 

 

 

4611, 4630

1.

Multiport/2 Interface Board

 

 

2.

Multiport/2 Adapter

 

 

 

4612, 4613, 4640, 4641

1.

Memory Module Package

 

 

2.

Multiport/2 Adapter

 

 

 

4650

1.

Multiport/2 Interface Cable

 

 

 

 

46XX

1.

Multiport/2 Adapter

Not listed above

2.

Multiport/2 Interface

 

 

 

Board

 

3.

Memory Module

 

 

 

5600

1.

Financial System Controller Adapter

 

 

 

 

Chapter 7. Symptom-to-FRU Index 117

Page 123
Image 123
IBM 8302, 8309, 8308, 8312, 8313, 8311, 8310, 8315, 8314, 8301, 8306, 8304, 8303, 8305 manual Symptom-to-FRU Index