Types 8305, 8306, 8309, and 8313

Notes:

1.The BIOS and Vital Product Data (VPD) for the computer you are servicing must be installed on the new system board (FRU) after it is installed in the computer. To do this, you must run the Flash Update program using the Flash Update diskette. See “BIOS levels” on page 265, “Vital product data” on page 264, and “Flash update procedures” on page 265.

2.Always ensure the latest level of BIOS is installed on the computer. A down level BIOS may cause false errors and unnecessary replacement of the system board.

3.The processor is a separate FRU from the system board and is not included with the system board FRU.

4.If the new system board does not correct the problem, reinstall the options on the old system board, reinstall the old system board, then replace the processor.

1.Remove the cover. See “Removing the cover” on page 40.

2.Remove the 7 screws that attach the system board to the chassis.

3.Remove the board from the chassis.

4.Remove the processor from the old system board and install it on the new system board.

5.Remove any memory modules on the old system board, and install them on the new system board.

6.Ensure that the new system board jumper settings match the old system board jumper settings.

82Hardware Maintenance Manual

Page 88
Image 88
IBM 8311, 8308, 8312, 8313, 8310, 8315, 8314, 8301, 8304, 8302, 8303 manual Types 8305, 8306, 8309