Diagnostic Error Code

FRU/Action

 

 

 

071-199-XXX

1.

Go to the Undetermined problems

Audio port test failed, cause unknown

 

section

 

 

 

2.

Flash the system and re-test

 

3.

Replace component under function test

 

 

 

071-25X-XXX

1.

Speakers

Audio port failure

2.

Audio card, if installed

 

 

3.

System board

 

 

 

080-000-XXX

1.

No action

Game Port interface Test Passed

 

 

 

 

 

080-XXX-XXX

1.

Remove the game port device and

Game Port interface Error

 

re-test the system

 

 

 

 

 

080-195-XXX

1.

Information

Game Port interface Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

080-196-XXX

1.

Press F3 to review the log file

Game Port interface test halt, error threshold

2.

Re-start the test to reset the log file

exceeded

 

 

080-197-XXX

1.

Make sure the component that is called

Game Port interface test warning

 

out is connected and/or enabled

 

 

 

2.

Re-run test

 

3.

Component that is called out in warning

 

 

statement

 

4.

Component under test

 

 

 

080-198-XXX

1.

If a component is called out, make sure

Game Port interface test aborted

 

it is connected and/or enabled

 

 

 

2.

Flash the system and re-test

 

3.

Go to the Undetermined problems

 

 

section

 

 

 

080-199-XXX

1.

Go to the Undetermined problems

Game Port interface test failed, cause

 

section

unknown

 

2.

Flash the system and re-test

 

 

3.

Replace component under function test

 

 

 

086-000-XXX

1.

No action

Mouse Port interface Test Passed

 

 

 

 

 

086-001-XXX

1.

Mouse

Mouse Port interface Presence

2.

System board

 

 

 

 

086-032-XXX

1.

Mouse

Mouse Port interface Device controller

2.

System board

failure

 

 

 

 

 

086-035-XXX

1.

Mouse

Mouse Port interface Reset

2.

System board

 

 

 

 

086-040-XXX

1.

Run Setup

Mouse Port interface IRQ failure

2.

Mouse

 

 

3.

System board

 

 

 

086-195-XXX

1.

Information

Mouse Port interface Test aborted by user

2.

Re-start the test, if necessary

 

 

 

 

102Hardware Maintenance Manual

Page 108
Image 108
IBM 8304 071-25X-XXX Speakers, XXX No action, Remove the game port device, Re-test the system, XXX Information, XXX Mouse