Installation and Configuration
Initial Inspection
| JUMPER SELECTION | |
J2 | Local OVP control selection | [closed] [default]. See page 23. |
|
| [open] Front Panel OVP Control. |
J3 | User TTL shutdown (S/D) selection | |
|
| See page 27. |
|
| |
J20 | Remote OVP Control Selection | [closed] [default]. See page 23. |
|
| [open] |
Note: All other jumpers are not
|
| LED INDICATORS |
D1 | Red Diagnostic LED | Bus error or soft restart on Slave circuitry. |
D4 | Red Diagnostic LED | Soft restart on Master circuitry. |
D5 | Green Diagnostic LED | Bus error on Master circuitry. |
|
| See page 48. |
|
| EPROMS |
U18 | Slave EPROM | See revision number stamped on EPROM. |
U1 | Master EPROM | See revision number stamped on EPROM. |
Figure 2.3 GPIB Interface PCB
18 | Operating Manual for GPIB for XPD Series Power Supply |