Features and Specifications
Specifications
Specifications
The specifications in this section are warranted at 25°C ±5°C unless otherwise specified. All specifications are subject to change without notice.
Table 1.1 Specifications for XPD 500 W Series Supply with GPIB Interface Installed
Models |
|
|
|
| |
Program Resolution |
|
|
|
|
|
Voltage | 1.2mV | 4.6mV | 5.1mV | 9.3mV | 18.6mV |
Current | 5.2mA | 3.6mA | 2.9mA | 1.3mA | 0.7mA |
OVP | 1.2mV | 4.6mV | 5.1mV | 9.3mV | 18.6mV |
Program Accuracy1 |
|
|
|
|
|
Voltage | 10mV | 75mV | 75mV | 150mV | 180mV |
| ±0.12% | ±0.12% | ±0.12% | ±0.3% | ±0.25% |
Current | 250mA | 140mA | 115mA | 80mA | 80mA |
| ±0.1% | ±0.1% | ±0.15% | ±0.15% | ±0.1% |
OVP | 80mV | 200mV | 330mV | 600mV | 1.2V |
Readback Resolution |
|
|
|
|
|
Voltage | 1.2mV | 4.6mV | 5.1mV | 9.3mV | 18.6mV |
Current | 5.2mA | 3.6mA | 2.4mA | 1.3mA | 0.7mA |
Readback Accuracy1 |
|
|
|
|
|
Voltage | 30mV | 75mV | 75mV | 150mV | 180mV |
| ±0.12% | ±0.12% | ±0.2% | ±0.3% | ±0.25% |
Current | 250mA | 140mA | 115mA | 80mA | 80mA |
| ±0.1% | ±0.1% | ±0.15% | ±0.15% | ±0.1% |
1.Apply accuracy specifications according to the following voltage program accuracy example: Set a model XPD
The expected result will be within the range of 10 volts ± 75mV ± 0.12% of the set voltage of 10 volts.
Release 1.2 | 13 |