Xerox Phaser 3120 specifications Troubleshooting, How to use DCU 4.1.1 DCU Setup

Models: Phaser 3120

1 81
Download 81 pages 13.25 Kb
Page 21
Image 21

4 TROUBLESHOOTING

4. Troubleshooting

4.1 How to use DCU 4.1.1 DCU Setup

You can examine the malfunction of the printer. To perform DCU, open the front discharge cover and leave the connect the harness wire(10 pin/4 pin) to the CN10(4 pin) of the Main control board.

ML SERIES DIAGNOSTIC CONTROL UNIT

STATUS

DIAGNOSTIC

04

DEV 300

DEV 350

DEV 350

05

LSU READY

LSU MT & LD

LSU MOTOR

07

PAPER EMPTY

PAPER WIDTH

NEW CRU

08

 

EXIT SENSOR

FEED SENSOR

09

COVER OPEN

 

 

10

COER HEATING

PRINTING TEMP

READY HEAT

 

 

 

 

 

ON

OFF

 

 

 

 

 

SELF TEST

DIAGNOSTIC CODE

00MAIN MOTOR OPERATING SYSTEM

01MAIN HIGH-VOLTAGE ON

02TRNSFER HIGH-VOLTAGE (-)ON

03THV(+) REFERANCE VOLTAGE

04DEV/SUPPLY HIGH-VOLTAGE ON/PTL ON

05LSU OPERATING SYSTEM

06PICKUP CLUTCH ON

07

PEEMPTY/PWITH/NEW CRU TEST

08

FEED & EXIT SENSOR TEST

09COVER OPEN SENSOR TEST

10FUSER TEST

11HOT BURN TEST

12CLEAN MODE PRINT

13THV(+)TRIGGER, ALL HV & FAN ON

14THV(+) REFERENCE ON

STATUS CODE

61 WARM UP

00READY (REGAL)

01READY (LETTER)

02READY (A4)

03READY (EXECUTIVE)

04READY (B5)

20 PRINT START

30FEED SENSOR ON 40￿ FEED SENSOR OFF

50PAPER OUT

69 SLEEP MODE

￿

ERROR STATUS CODE

60￿ OPEN FUSER ERROR

62￿ LOW TEMPERATURE ERROR 68￿ OVER HEATING ERROR 64￿ COVER OPEN ERROR

70￿ NO PAPERR

71￿ PAPER JAM 0

72￿ PAPER JAM 1

73￿ PAPER JAM 2

95 LSU NOT READY

DIAGNOSTIC

 

DOWN

 

SHIFT

 

STOP

 

 

 

MODE

 

UP

 

 

 

ENTER

TO ENTER DIAGNOSTIC MODE, PUSH THREE BUTTONS SIMUL ANEOUSL AND TURN THE PRINTER POWER ON.