Auto Scene Memory Update 165
01V96—Owner’s Manual
Scene Memories
15
GPATCH LINK INPUT
HPATCH LINK OUTPUT
These parameters indicate the Input and Output Patch library numbers selected at the
time the Scenes were stored. When you recall a Scene, the linked Input or Output patch
is recalled as well. You can also move the cursor to the parameter boxes and change the
library numbers.
Auto Scene Memory Update
If the Scene MEM Auto Update check box on the Setup | Prefer1 page (see page 226) is
turned on, parameter edits are stored automatically in a Shadow memory, which is avail-
able for each Scene. This is called the Auto Update function.
If the Auto Update function is enabled, parameter edits made after the Scene was recalled
are stored in the Scene’s Shadow memory. When you again recall the Scene, the contents of
the Original and Shadow memories are recalled alternately.
Therefore, even after you recall the Original Scene memory, you can recall the edited
version from Shadow memory to restore the most recent edits.
If the “EDIT” indicator appears at the top of the display, the edited version from Shadow
memory has been recalled.
If a Shadow memory is recalled, the edited version is stored when you store the Scene. (The
contents of the Original and Shadow memories then become identical.) When you recall
Scenes via MIDI Program Change messages, the contents of the Original memory are
always recalled, even if the Auto Update function is enabled.
Display
Edit indicator
Original Scene Shadow memory