204 Chapter 17—Remote Control
01V96—Owner’s Manual
2 Press the DISPLAY ACCESS [DIO/SETUP] button repeatedly until the
DIO/Setup | MIDI/Host page appears.
3 Move the cursor to the REMOTE parameter box (1) in the SPECIAL FUNC-
TIONS section, rotate the Parameter wheel to select MIDI, then press
[ENTER].
If the MIDI port is already in use, a window confirming the assignment change appears.
Move the cursor to the YES button, then press [ENTER].
4 Press the DISPLAY ACCESS [DIO/SETUP] button repeatedly until the
DIO/Setup | Remote page appears.
5Move the cursor to the TARGET parameter box, rotate the Parameter wheel
to select USER DEFINED, then press [ENTER].
The confirmation window for changing the setting appears. Move the cursor to the YES
button, then press [ENTER]. The display changes as follows:
ATRANSMIT ENABLE/DISABLE
This button switches the MIDI Remote function between enable and disable.
BINITIALIZE
This button resets the settings stored in the bank selected by the BANK parameter their
default settings.
CBANK
This parameter enables you to select one of four banks.
Tip: If the REMOTE parameter box is grayed out, proceed to Steps 4 and 5 to set the TARGET
parameter, then return to Steps 2 and 3.
1
2
3
5
6
1
4