168 Chapter 15—Scene Memories
01V96—Owner’s Manual
Recalling Scenes Safely
When a Scene is recalled, all mix parameters are set accordingly. However, in some situa-
tions, you can retain the current settings of certain parameters on certain channels by
using the Recall Safe function. Recall Safe settings are stored in Scene memories.
To set the Recall Safe function, press the DISPLAY ACCESS [SCENE] button repeatedly
until the Scene | Rcl Safe page appears.
AGlobal Recall Safe
When this check box is checked, Recall Safe settings stored in Scene memories are
ignored and the current settings are retained.
BSAFE
This parameter enables or disables the Recall Safe function.
CMODE
The following MODE buttons determine which Safe channel parameters will remain
unaffected by Scene recalls. The MODE buttons correspond to the following parame-
ters:
ALL................................ All parameters
FADER...........................Channel faders (or level controls)
ON..................................Channel On/Off parameters
PAN ................................Channel Pan parameters
EQ.................................. Channel EQ parameters
COMP............................Channel Comp parameters
GATE............................. Channel Gate parameters
AUX ...............................Channel Aux Send levels
AUX ON........................Aux Send On/Off parameters
DRECALL SAFE CHANNEL section
This section enables you to select which channels will remain unaffected by Scene
recalls, including Input Channels 1–32, ST IN Channels 1–4, Bus Outs 1–8, Aux Outs
1–8, Stereo Out, internal effects processors. The Recall Safe function is effective on chan-
nels and effects for which the buttons are turned on.
Tip: The ALL button is mutually exclusive of the other buttons.
2
3
4
1